Partially Connected Operation

نویسندگان

  • Larry B. Huston
  • Peter Honeyman
چکیده

RPC latencies and other network-related delays can frustrate mobile users of a distributed file system. Disconnected operation helps, but fails to use networking opportunities to their full advantage. In this paper we describe partially connected operation, an extension of disconnected operation that resolves cache misses and preserves client cache consistency, but does not incur the write latencies of a fully connected client. Benchmarks of partially connected mode over a slow network indicate overall system performance comparable to fully connected operation over Ethernet.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

A Toolkit Approach to Partially Connected Operation

Partially connected operation is the circumstance in which the communication link between two computers is intermittent, either by choice or because or failure. This paper describes the design and performance of a user level toolkit that is suited to accessing the home directory of a partially connected user in a bandwidth-eecient manner. Compared to custom le systems for partially connected op...

متن کامل

Model Predictive Control of Distributed Energy Resources with Predictive Set-Points for Grid-Connected Operation

This paper proposes an MPC - based (model predictive control) scheme to control active and reactive powers of DERs (distributed energy resources) in a grid - connected mode (either through a bus with its associated loads as a PCC (point of common coupling) or an MG (micro - grid)). DER may be a DG (distributed generation) or an ESS (energy storage system). In the proposed scheme, the set - poin...

متن کامل

Optimal Operation Management of Grid-connected Microgrid Using Multi-Objective Group Search Optimization Algorithm

Utilizing distributed generations (DGs) near load points has introduced the concept of microgrid. However, stochastic nature of wind and solar power generation as well as electricity load makes it necessary to utilize an energy management system (EMS) to manage hourly power of microgrid and optimally supply the demand. As a result, this paper utilizes demand response program (DRP) and battery t...

متن کامل

Operation of Stand Alone PV Generating System for Supplying Unbalanced AC Loads

This paper describes a DC isolated network which is fed with Distributed Generation (DG) from photovoltaic (PV) renewable sources for supplying unbalanced AC loads. The battery energy storage bank has been connected to the DC network via DC/DC converter to control the voltage of the network and optimize the operation of the PV generation units. The PV arrays are connected to the DC network ...

متن کامل

Performance Analyzing of CMOS Gates by Sub Clocking Method Using Cadence Tools

Reducing the power consumed by the device is the emerging trend. The aim of this project is to reduce the leakage current of the circuit by using the Sub Clocking technology. It is the process of switching the circuit by means of partially ON to reduce the power consumption. In this paper there are two modes of operation are implemented.1. Half mode operation, 2. Full mode operation. This mode ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 1995