A multicentre study of the long-term results of using a flat-back polyethylene glenoid component in shoulder replacement for primary osteoarthritis.

نویسندگان

  • A Young
  • G Walch
  • P Boileau
  • L Favard
  • F Gohlke
  • M Loew
  • D Molé
چکیده

We report the long-term clinical and radiological outcomes of the Aequalis total shoulder replacement with a cemented all-polyethylene flat-back keeled glenoid component implanted for primary osteoarthritis between 1991 and 2003 in nine European centres. A total of 226 shoulders in 210 patients were retrospectively reviewed at a mean of 122.7 months (61 to 219) or at revision. Clinical outcome was assessed using the Constant score, patient satisfaction score and range of movement. Kaplan-Meier survivorship analysis was performed with glenoid revision for loosening and radiological glenoid loosening (SD) as endpoints. The Constant score was found to improve from a mean of 26.8 (SD 10.3) pre-operatively to 57.6 (SD 20.0) post-operatively (p < 0.001). Active forward flexion improved from a mean of 85.3° (SD 27.4) pre-operatively to 125° (SD 37.3) postoperatively (p < 0.001). External rotation improved from a mean of 7° (SD 6.5) pre-operatively to 30.3° (SD 21.8°) post-operatively (p < 0.001). Survivorship with revision of the glenoid component as the endpoint was 99.1% at five years, 94.5% at ten years and 79.4% at 15 years. Survivorship with radiological loosening as the endpoint was 99.1% at five years, 80.3% at ten years and 33.6% at 15 years. Younger patient age and the curettage technique for glenoid preparation correlated with loosening. The rate of glenoid revision and radiological loosening increased with duration of follow-up, but not until a follow-up of five years. Therefore, we recommend that future studies reporting radiological outcomes of new glenoid designs should report follow-up of at least five to ten years.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Incidence of early development of radiolucent lines in keeled polyethylene glenoid components after total shoulder arthroplasty.

Glenoid loosening after total shoulder arthroplasty (TSA) remains a major concern. The purpose of this study was to determine the incidence of radiolucent lines (RLLs) after TSA performed with modern glenoid bone preparation and cement techniques for keeled-back glenoid components. One hundred ten consecutive patients with osteoarthritis were included in this study. Patients had undergone prima...

متن کامل

An in vitro study comparing limited to full cementation of polyethylene glenoid components

BACKGROUND Glenoid component survival is critical to good long-term outcomes in total shoulder arthroplasty. Optimizing the fixation environment is paramount. The purpose of this study was to compare two glenoid cementing techniques for fixation in total shoulder arthroplasty. METHODS Sixteen cadaveric specimens were randomized to receive peg-only cementation (CPEG) or full back-side cementat...

متن کامل

Comparison of Asymmetric Reaming versus a Posteriorly Augmented Component for Posterior Glenoid Wear and Retroversion: A Radiographic Study

Background: Managing posterior glenoid wear and retroversion remains a challenge in shoulder arthroplasty.Correcting glenoid version through asymmetric reaming (AR) with placement of a standard glenoid component and theuse of posteriorly augmented glenoid (PAG) components are two methods used to address this problem. Our objectiveis to report the radiographic outcomes of patie...

متن کامل

Total shoulder arthroplasty for glenohumeral arthritis associated with posterior glenoid bone loss: results of an all-polyethylene, posteriorly augmented glenoid component.

BACKGROUND Posterior glenoid bone loss is commonly encountered in total shoulder arthroplasty (TSA). The purpose of our study is to report the clinical and radiographic findings of patients with a minimum of 2 years' follow-up treated with an all-polyethylene, augmented glenoid component. METHODS Twenty-two shoulders with posterior glenoid bone loss were treated by a single surgeon. All under...

متن کامل

Mid-term results of a metal-backed glenoid component in total shoulder replacement.

Total shoulder replacement is a successful procedure for degenerative or some inflammatory diseases of the shoulder. However, fixation of the glenoid seems to be the main weakness with a high rate of loosening. The results using all-polyethylene components have been better than those using metal-backed components. We describe our experience with 35 consecutive total shoulder replacements using ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Journal of bone and joint surgery. British volume

دوره 93 2  شماره 

صفحات  -

تاریخ انتشار 2011