Influence of disinfectant solutions on test materials used for the determination of masticatory performance.

نویسندگان

  • Simone Silvério Campos
  • Cássio Vicente Pereira
  • Márcio Gilberto Zangerônimo
  • Leandro Silva Marques
  • Luciano José Pereira
چکیده

Masticatory function can be evaluated objectively as the capacity of an individual to fragment solid food after a fixed number of chewing cycles, the so-called masticatory performance (MP). The objective of this study was to evaluate the reliability of four different test materials (Optosil, Optocal, Zetapuls, and Perfil) and five disinfection protocols by aspersion and immersion (no disinfection, 2% glutaraldehyde, 2% chlorhexidine, 5.25% sodium hypochlorite, and 70% alcohol) on the MP, determined at three moments (24 hours, 15 and 60 days) after storing the fragmented blocks. MP was evaluated by calculating X50 through the sieving technique and the Rosim-Ramler equation. The weight and microbiologic count (colony forming units, CFUs) of chewed blocks were measured to identify any variations that would make MP determination unfeasible. Differences in MP were observed among the materials (p < 0.01). Perfil presented the highest X50 value (worst MP determination), followed by Zetaplus (both p < 0.05), Optosil, and Optocal (both p > 0.05). The time and disinfection type had no influence on MP (p > 0.05). The number of CFUs differed between the nondisinfected group and all other disinfection groups at all time points (p < 0.01). No other significant difference in CFU count between disinfection groups was observed. In conclusion, disinfection did not alter the reliability of the test materials for the MP calculation for up to 60 days.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقایسه آلودگی زدایی مخروطهای گوتاپرکا با سه نوع محلول ضدعفونی کننده در مدت زمان یک دقیقه

Background and Aim: Care must be taken during root canal therapy to prevent contamination of filling materials and avoid root canal contamination. Gutta-percha cones are now widely used to fill root canals. However they are not resistant to conventional sterilization processes in moist or dry heat. To keep the aseptic chain, gutta-percha cones require rapid chair side decontamination before use...

متن کامل

بررسی اثر ضدمیکروبی 4 محلول ضدعفونی کننده بر هندپیس‌های آلوده به استافیلوکوک طلایی، پسودوموناس آئروژینوزا و کاندیدا آلبیکنس

Background and Aim: Contaminated dental handpieces have the potential to transfer infection to patients. New generation of autoclavable turbines have to some extent overcome the problem however, in clinic sometimes it is necessary to use chemical to disinfect handpieces. The aim of this study was to determine the antimicrobial effect of some routinely used disinfectant solutions on dental conta...

متن کامل

A Comparative Study on the Effectiveness of Different Hand Disinfectant Solutions Used in Surgical Scrub

Background and Objectives: Hand hygiene is a crucial measure for preventing healthcare-related infections. Surgical scrub is an important factor in the safety and success of a surgical operation. The aim of this study was to comparatively evaluate effectiveness of some conventional surgical antiseptic solutions, and to identify the most effective one. Methods: Effectiveness of alcohol-based s...

متن کامل

Dynamic Modeling of the Electromyographic and Masticatory Force Relation Through Adaptive Neuro-Fuzzy Inference System Principal Dynamic Mode Analysis

Introduction: Researchers have employed surface electromyography (EMG) to study the human masticatory system and the relationship between the activity of masticatory muscles and the mechanical features of mastication. This relationship has several applications in food texture analysis, control of prosthetic limbs, rehabilitation, and teleoperated robots. Materials and Methods: In this paper, w...

متن کامل

Dimensional change of elastomeric materials after immersion in disinfectant solutions for different times.

AIM The aim of this study was to evaluate the influence of immersion period in two disinfectant solutions on dimensional change of four elastomeric impression materials. MATERIALS AND METHODS Four representative materials of each class of elastomers: Xantopren (polydimethylsiloxane-PDS), Express (polyvinyl siloxane-PVS); Permlastic (polysulfide- PS) and Soft Impregum (polyether-EP) were mixed...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Brazilian oral research

دوره 27 3  شماره 

صفحات  -

تاریخ انتشار 2013