A sewing needle completely buried in the myocardium removed under extracorporeal circulation.
نویسندگان
چکیده
A 14-year-old boy had a needle accidentally inserted through his chest wall. Chest X-ray showed a needle-shaped metallic density localized in the cardiac silhouette. An echocardiography indicated the needle had passed through the interventricular septum, and its eye and point had reached the right and left ventricle, respectively. Surgical removal of the needle was performed. The needle could not be observed from the heart surface, and was recognized in a dent 5 mm on the right side from the left anterior descending branch (LAD). The needle was easily removed under extracorporeal circulation, and he was discharged ten days after the operation.
منابع مشابه
Surgical Removal of an Intracardiac Sewing Needle in a 13-Month-Old Chinese Girl: Report of a Case
Abstract Introduction: Sewing needles, albeit a rare case of penetrating cardiac injury, are highly lethal, especially in children, because it is difficult to diagnose and treat. We herein present the case of a 13-month-old girl who was injured by a sewing needle inserted in the myocardium, which probably is the first report from mainland China.Case presentation: The 13-month-old girl was refer...
متن کامل[Intracardiac sewing needle in a women with autoaggressive behavior].
Heart lesions produced by the introduction of sewing needles into the thorax by people with autoagressive behavior patterns are very rare.1-4 Such patients usually suffer psychiatric disorders and present at hospital manifesting that they have introduced a foreign object into their chest, or with chest pain, dyspnea and sometimes pneumothorax. We recently treated a female drug addict with psych...
متن کاملLaparoscopic Removal of a Broken Sewing Needle in a Patient with Irritative Bladder Symptoms
A foreign body near the bladder is rare. Although foreign bodies in the bladder can be easily found and removed by endoscopic transurethral removal, extravesical foreign bodies may require the use of an open or laparoscopic procedure. Here, we report a case of a patient complaining of frequency and urgency in whom an extravesical sewing needle was successfully removed by a laparoscopic approach...
متن کاملA sewing needle in contact with the cervical dura mater and vertebral artery: A case report: Erratum
RATIONALE Although cervical foreign bodies have been previously reported, the report of a needle in the cervical spinal cord is rare. Herein, we report a rare case of a sewing needle in contact with the cervical dura mater and vertebral artery. PATIENTS CONCERNS A 47-year-old man presented with discomfort in the posterior region of his neck. Approximately 2 years before admission, he suffered...
متن کاملTracheal Chondrosarcoma Excised With Extracorporeal Circulation
Introduction: Tracheal chondrosarcoma (TCS) is a rare malignancy, with only 19 cases described in the literature to date. Case presentation: Herein, we presented the third-largest TCS with such an airway compromise that neither orotracheal intubation nor jet ventilation or even tracheostomy was possible. So, extracorporeal circulation was needed to excise the tumor in a one-stage procedure. Th...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Annals of thoracic and cardiovascular surgery : official journal of the Association of Thoracic and Cardiovascular Surgeons of Asia
دوره 12 3 شماره
صفحات -