Accuracy of ventricular volume estimation.

نویسندگان

  • D J Wyper
  • J D Pickard
  • M Matheson
چکیده

Sources of error in the estimation of ventricular volume from CAT scans are discussed and the accuracy of the measurement assessed. Two methods of calculating ventricular volume from an intraventricular injection of radioisotope are described and compared. Finally, the CAT scan and isotope methods are compared and contrasted. The error associated with a single measurement of volume by any of these techniques is between 20% and 30%. In patients with no ventricular catheter there is no choice other than to use CAT scanning, but if intraventricular injection is possible this method offers a potentially more accurate volume determination because of his higher signal-to-noise ratio.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

ارزیابی دیداری تخمین حجم خون‌ریزی بعد از زایمان و چگونگی درمان

Background: Postpartum hemorrhage is a leading cause of maternal morbidity and mortality that is preventive by appropriate estimation of blood loss and its treatment. This study was undertaken to evaluate the accuracy of visual estimation of postpartum hemorrhage by clinicians and co worker who work in the obstetrics department. Methods: In this descriptive observational study, 199 educational...

متن کامل

Use of biplane cinefluorography for measurement of ventricular volume.

A biplane cinefluorographic technic for measuring ventricular volume is described and its accuracy and limitations are assessed. Although rather complicated and time-consuming at present, the method permits construction of volume curves and estimation of stroke volume of the left ventricle for several successive contractions in the intact animal or man. This method may prove ultimately for diag...

متن کامل

Improved accuracy in estimation of left ventricular function parameters from QGS software with Tc-99m tetrofosmin gated-SPECT: a multivariate analysis.

UNLABELLED The purpose of this study was to verify whether the accuracy of left ventricular parameters related to left ventricular function from gated-SPECT improved or not, using multivariate analysis. METHODS Ninety-six patients with cardiovascular diseases were studied. Gated-SPECT with the QGS software and left ventriculography (LVG) were performed to obtain left ventricular ejection frac...

متن کامل

A Study on the Accuracy and Precision of Estimation of the Number, Basal Area and Standing Trees Volume per Hectare Using of some Sampling Methods in Forests of NavAsalem

   The present study aimed to investigate the accuracy and precision estimation of the number, basal area and volume of the standing trees by methods of random and systematic random sampling in the forests of West Guilan. The cost or inventory time was determined using the criteria (E%2 × T). Inventory was carried out by complete sampling (census) in an area of 52 hectares. The study area (sect...

متن کامل

Calibrating volume measurements made using the dual-field conductance catheter

The conductance catheter technique allows realtime measurements of ventricular volume based on changes in the electrical conductance of blood within the ventricular cavity. Conductance volume measurements are corrected with a calibration coefficient, α, in order to improve accuracy. However, conductance volume measurements are also affected by parallel conductance, which may confound calibratio...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Journal of neurology, neurosurgery, and psychiatry

دوره 42 4  شماره 

صفحات  -

تاریخ انتشار 1979