Optimising Cell Aggregate Expansion in a Perfused Hollow Fibre Bioreactor via Mathematical Modelling

نویسندگان

  • Lloyd A. C. Chapman
  • Rebecca J. Shipley
  • Jonathan P. Whiteley
  • Marianne J. Ellis
  • Helen M. Byrne
  • Sarah L. Waters
چکیده

The need for efficient and controlled expansion of cell populations is paramount in tissue engineering. Hollow fibre bioreactors (HFBs) have the potential to meet this need, but only with improved understanding of how operating conditions and cell seeding strategy affect cell proliferation in the bioreactor. This study is designed to assess the effects of two key operating parameters (the flow rate of culture medium into the fibre lumen and the fluid pressure imposed at the lumen outlet), together with the cell seeding distribution, on cell population growth in a single-fibre HFB. This is achieved using mathematical modelling and numerical methods to simulate the growth of cell aggregates along the outer surface of the fibre in response to the local oxygen concentration and fluid shear stress. The oxygen delivery to the cell aggregates and the fluid shear stress increase as the flow rate and pressure imposed at the lumen outlet are increased. Although the increased oxygen delivery promotes growth, the higher fluid shear stress can lead to cell death. For a given cell type and initial aggregate distribution, the operating parameters that give the most rapid overall growth can be identified from simulations. For example, when aggregates of rat cardiomyocytes that can tolerate shear stresses of up to 0:05 Pa are evenly distributed along the fibre, the inlet flow rate and outlet pressure that maximise the overall growth rate are predicted to be in the ranges 2.75 x 10(-5) m(2) s(-1) to 3 x 10(-5) m(2) s(-1) (equivalent to 2.07 ml min(-1) to 2.26 ml min(-1)) and 1.077 x 10(5) Pa to 1.083 x 10(5) Pa (or 15.6 psi to 15.7 psi) respectively. The combined effects of the seeding distribution and flow on the growth are also investigated and the optimal conditions for growth found to depend on the shear tolerance and oxygen demands of the cells.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Multiphase modelling of the influence of fluid flow and chemical concentration on tissue growth in a hollow fibre membrane bioreactor.

A 2D model is developed for fluid flow, mass transport and cell distribution in a hollow fibre membrane bioreactor. The geometry of the modelling region is simplified by excluding the exit ports at either end and focusing on the upper half of the central section of the bioreactor. Cells are seeded on a porous scaffold throughout the extracapillary space (ECS), and fluid pumped through the biore...

متن کامل

Periodic harvesting of embryonic stem cells from a hollow-fiber membrane based four-compartment bioreactor.

Different types of stem cells have been investigated for applications in drug screening and toxicity testing. In order to provide sufficient numbers of cells for such in vitro applications a scale-up of stem cell culture is necessary. Bioreactors for dynamic three-dimensional (3D) culture of growing cells offer the option for culturing large amounts of stem cells at high densities in a closed s...

متن کامل

Multiphase modelling of the effect of fluid shear stress on cell yield and distribution in a hollow fibre membrane bioreactor

We present a simplified two-dimensional model of fluid flow, nutrient transport and cell distribution in a hollow fibre membrane bioreactor, with the aim of exploring how fluid flow can be used to control the distribution and yield of a cell population which is sensitive to both fluid shear stress and nutrient concentration. The cells are seeded in a scaffold in a layer on top of the hollow fib...

متن کامل

Experimental evaluation and theoretical modeling of oxygen transfer rate for the newly developed hollow fiber bioreactor with three compartments.

Bioartificial liver support provides a bridge to transplantation which is at present the only proven specific treatment for acute liver failure. In this paper, a novel multi-coaxial hollow fiber bioreactor so-called "Fibre-in-Fibre FIF Bioartificial liver device" with three compartments is experimentally and mathematically studied. The mathematical model in this paper is an extension of Krogh c...

متن کامل

Modelling the Oxygen Distribution in a Perfused Bioreactor for Cartilage Production

Introduction. We describe a continuous modelling and simulation framework aimed at monitoring and steering a recently developed bioreactor for cartilage production based on mesenchymal stem cells (MSCs). This bioreactor provides online-access to the cell density by acoustic measuring sections. An appropriate oxygen distribution throughout the bioreactor is essential for a successful expansion a...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014