The Wire Scanner at Bepcii

نویسندگان

  • Y. F. Sui
  • J. S. Cao
چکیده

To monitor the beam profile in injector of BEPCII which is the upgrade project of Beijing Electron Positron Collider (BEPC). Several beam diagnostic and monitoring instruments are used. Wire scanner as a new diagnostic instrument was designed and manufactured to measure the beam profile at the end of linac in 2007.During the shutdown period of BEPCII we had installed the system at the end of linac. After that we had done beam test for several times. This paper describes the whole system of wire scanner and the result of several times beam test. Recent progresses and some discussion of the beam test result will also be present..

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

BEPCII and BESIII

The Beijing Electron Collider is being upgraded (BEPCII) to a two-ring collider with a design luminosity of 1 × 10cm s at a center-of-mass energy of 3.89 GeV. It will operate between 2 and 4.2 GeV in the center of mass. With this luminosity, the BESIII detector will be able to collect, for example, 10 billion J/ψ events in one year of running. This will be a unique facility in the world opening...

متن کامل

Lansce Wire Scanner Afe: Analysis, Design, and Fabrication*

The goal of the design LANSCE-R Wire-Scanner Analog Front-end Electronics is to develop a highperformance, dual-axis wire-scanner analog front-end system implemented in a single cRIO module. This new design accommodates macropulse widths as wide as 700μs at a maximum pulse rate of 120Hz. A lossey integrator is utilized as the integration element to eliminate the requirement for providing gating...

متن کامل

Measuring Micron Size Beams in the SLC Final Focus

A pair of high resolution wire scanners have been built and installed in the SLC final focus. The final focus optics uses a set of de-magnifying telescopes, and an ideal location for a beam size monitor is at one of the magnified image points of the interaction point. The image point chosen for these scanners is in the middle of a large bend magnet. The design beam spots here are about 2 micron...

متن کامل

The Beam Observation System of the Isolde Facility

During the reconstruction of the ISOLDE on-line mass separator facility at CERN one of the goals was the development and implementation of an efficient and user friendly beam observation system. The pick-up devices used on the two mass separators and the beam lines are mainly Faraday cups, wire scanners and wire grids. Most of these items were specifically designed at ISOLDE, in particular, a l...

متن کامل

Control System of the Bepcii

Recently the Chinese Academy of Sciences has chosen BEPCII as the future development of the Beijing Electron Positron Collider (BEPC), i.e. upgrade of both the machine and detector. The luminosity of the machine is expected to increase to 1.0x10cms. The project will be started at the beginning of 2002 and finished within 3-4 years. The BEPC control system was built in 1987 and upgraded in 1994....

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2010