Interferences removal for cadmium determination in samples with complex matrices by hydride generation coupled with non-dispersive atomic fluorescence spectrometry.

نویسندگان

  • Zhongxi Li
  • Liping Zhou
چکیده

An intermittent on-line concentration and separation system coupled with HG-AFS was developed to eliminate serious interferences from Cu2+, Pb2+ and Zn2+ on the determination of cadmium. In the present method, the interferences from common coexisting ions, such as Cu2+, Pb2+, Zn2+, Fe3+ and Ni2+, were greatly reduced. Under the optimized conditions, a detection limit of 3 pg ml(-1) (3sigma, n=11) and a precision of 1.9% RSD for 1 ng ml(-1) of Cd were obtained. The method was successfully applied to the determination of cadmium in a series of Chinese Geological Reference Materials (SRMs) and GBW01621 ferronickel alloy using simple aqueous standard calibration technique. The results obtained were in good agreement with the certified values.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Concentrations of hazardous heavy metals in environmental samples collected in Xiamen, China, as determined by vapor generation non-dispersive atomic fluorescence spectrometry.

Non-dispersive atomic fluorescence spectrometry (NDAFS) coupled with vapor generation (VG) sample introduction was applied to the determination of the concentrations of hazardous heavy metals, such as arsenic, cadmium, lead and mercury, in seawater, soils and total airborne particulate matter (PM) collected around the Xiamen area in China. Almost 100% sample introduction efficiency was achieved...

متن کامل

Simultaneous determination of trace cadmium and arsenic in biological samples by hydride generation-double channel atomic fluorescence spectrometry.

Hydride generation atomic fluorescence spectrometry (HG-AFS) has been used for determination of hydride-forming elements because of its high sensitivity, simplicity, and low costs, but most of such work has been concentrated on single element analysis, and reports dealing with multielement determination by HG-nondispersive (ND)AFS are rare. In this work, a sensitive HG-NDAFS method was develope...

متن کامل

Sepration and determination trace amount of cadmium ions in real and water samples by cloud point extraction - flame atomic absorption spectrophotometry after preconcentration with non-ionic surfactant Triton-X114

2-(3- indolyl) – 4,5 di phynyl imidazole.(IDPI) was used as a complexing agent in cloud point extraction for the first time and applied for selective pre-concentration of trace amounts of cadmium. The method is based on the extraction of cadmium at pH= 7.0 by using non-ionic surfactant Triton-X114 and 2-(3- indolyl) – 4,5 di phynyl imidazole. (IDPI) as a chelating agent. The adopted concentrati...

متن کامل

Determination of Cadmium by Electrothermal Atomic Absorption Spectrometry after its Separation and Preconcentration by Syringe to Syringe Dispersive Liquid Phase Microextraction-Solidified Floating Organic Drop

The application of syringe to syringe dispersive liquid phase microextraction-solidified floating organic drop was extended for the separation and preconcentration of trace amounts of cadmium ions from water and cereal samples. The extracted cadmium was quantified by electrothermal atomic absorption spectrometry. Factors affecting the complex formation as well as microextraction efficiency such...

متن کامل

Masking Agents Evaluation for Lead Determination by Flow Injection-Hydride Generation-Atomic Fluorescence Spectrometry Technique: Effect of KI, L-Cysteine, and 1,10-Phenanthroline

Hydride generation (HG) of lead technique presents interferences from foreign ions of complex matrix samples. In order to minimize these interferences, the effect of masking agents such as KI, L-cysteine, and 1,10-phenanthroline was studied in the absence and in the presence of selected interfering species (As, Cr, Cu, and Fe). Different modes of addition of masking agents were accomplished, th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Analytical sciences : the international journal of the Japan Society for Analytical Chemistry

دوره 22 1  شماره 

صفحات  -

تاریخ انتشار 2006