Computer-controlled automation of radioimmunoassay based on gel entrapment of antibody.

نویسندگان

  • D B Cottrell
  • E C Toren
  • J A Magnuson
  • S J Updike
چکیده

We describe a new, broadly applicable approach to radioimmunoassay. Solid-phase binding reagent is prepared by entrapping antibody in polyacrylamide gel. This gel is then fragmented, sieved, and dehydrated in 95 percent ethanol. Upon evaporation of the ethanol, the dry antibody-gel particles are dispensed into miniature disposable plastic columns. A unidirectional flowing stream configuration is used to construct a standard curve for the polypeptide hormone, angiotensin I, used here to exemplify the technique. Good reproducibility of this standard curve is demonstrated. The analytical system includes a computer-controlled sample turntable, digital pipet, and liquid-switching assembly.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Gel entrapment of antibody: a new strategy for facilitating both manual and automated radioimmunoassay.

A technique of radioimmunoassay is presented that eliminates pipetting and centrifugation, and excludes interferences by high-molecular-weight materials from the incubation and separation steps. A solidphase binding reagent is prepared by first entrapping antibody in polyacrylamide gel. This gel is then fragmented, sieved, dried with ethanol or lyophilized, and placed in miniature disposable ch...

متن کامل

Practical automation and interpretation of quantitative assays of antibodies to therapeutic proteins, illustrated with human growth hormone.

To quantify concentrations of anti-growth hormone antibody in less than 600 serum samples by radioimmunoassay, we devised a system ("BOLAC") to process data and to execute the curve-fitting program LIGAND-PC automatically with an IBM PC-compatible computer. We fit data from each sample to four binding and one or two-antibody binding sites. Total antibody concentration is then calculated from th...

متن کامل

Fixture Design Automation and Optimization Techniques: Review and Future Trends

Fixture design is crucial part of manufacturing process. Fixture design is a critical design activity process, in which automation plays an integral role in linking computer-aided design (CAD) and computer-aided manufacturing (CAD). This paper presents a literature review in computer aided fixture design (CAFD) in terms of automation and optimization techniques over the past decades. First, the...

متن کامل

Preparation and Characterization of Thermoresponsive In-situ Forming Poloxamer Hydrogel for Controlled Release of Nile red-loaded Solid Lipid Nanoparticles

Preparation and characterization of thermoresponsive in-situ forming poloxamer hydrogel for controlled release of Nile red-loaded solid lipid nanoparticles. Nanoparticles (NPs) are cleared rapidly from systemic circulation and do not provide sustained action in most cases. To solve this problem, this investigation introduces an erodible in-situ forming gel system as potential vehicles for prolo...

متن کامل

Formulation of mefenamic acid loaded transfersomal gel by thin film hydration technique and hand shaking method

Objective(s): The aim of present study is to formulate mefenamic acid transdermal gel based on vesicular drug delivery approaches.Materials and Methods: For the preparation of mefenamic acid transdermal gel, transfersomes were selected as colloidal carriers. Transfersomes were prepared by hand shaking and thin film hydration techniques. The obtained transfersomes were characterized for vesicula...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Clinical chemistry

دوره 21 7  شماره 

صفحات  -