How to verify the calibration of Goldmann tonometers
نویسنده
چکیده
measuring the intraocular pressure (IOP), the fluid pressure inside the eye. It is an important test in the evaluation of patients with glaucoma, as damage to the optic nerve is more likely to occur in patients with high IOP. Most tonometers are calibrated to measure pressure in millimeters of mercury (mmHg). Goldmann tonometry is considered to be the gold standard test for IOP and is the most widely accepted method. A disinfected prism is mounted on the tonometer head and placed against the cornea. The force applied to the tonometer head is then adjusted using a dial connected to a variable tension spring until the pressure in the eye can be determined from the force applied (see page 60 for a detailed description of how to use a tonometer). Tonometers in busy clinics have been shown to lose accuracy within months of purchase or calibration by the manufacturer. They are more likely to deviate into the positive range, resulting in higher IOP measurements. It is essential that all eye units develop protocols for calibration checks. Ideally, tonometers should be checked for calibration errors on a monthly basis by individuals who can be held responsible for ensuring their accuracy.
منابع مشابه
Prevalence of Calibration Errors in Goldmann Applanation Tonometers
PURPOSE To determine the prevalence of calibration errors in Goldmann applanation tonometers at Farabi Eye Hospital. METHODS This cross-sectional study was performed on all tonometers in use at Farabi Eye Hospital. All Haag-Streit Goldmann applanation tonometers were checked according to the manufacturer's method by two independent observers and by a third observer in case of mismatched resul...
متن کاملHave You Tested Your Goldmann Tonometer Today?
Intraocular pressure (IOP) is the only known modifiable risk factor for glaucoma. Besides being a cornerstone in glaucoma management, accurate measurement of IOP forms an important component of routine ophthalmic evaluation. Despite the innovation of various newer tonometers, Goldmann applanation tonometer is still considered the Gold standard for IOP measurement. However, there are several rep...
متن کاملTonometer calibration in Brasília, Brazil.
PURPOSE To determine calibration errors of Goldmann applanation tonometers in ophthalmic clinics of Brasília, Brazil, and correlate the findings with variables related to tonometers model and utilization. METHODS Tonometers from ophthalmic clinics in Brasília, Brazil, were checked for calibration errors. A standard Goldmann applanation tonometer checking tool was used to asses the calibration...
متن کاملIntraocular Pressure Measurements by Three Different Tonometers in Children with Aphakic Glaucoma and a Thick Cornea
Background: To evaluate the agreement in intraocular pressure (IOP) measurements by Ocular Response Analyzer (ORA) and Tono-Pen XL (TXL) with the Goldmann Applanation Tonometer (GAT) and to examine corneal biomechanical properties in aphakic glaucoma patients with a central corneal thickness (CCT) >600 µ. Methods: Thirty-six eyes of aphakic glaucoma patients (group 1) and 40 eyes of normal chil...
متن کاملGoldmann applanation tonometry in the conscious rat.
PURPOSE To determine whether the Goldmann applanation tonometer can be modified to measure intraocular pressure (IOP) in the conscious rat. METHODS In anesthetized rats Goldmann tonometers were tested that had reduced biprism angles in the applanating tips and reduced weights in the tonometer body from those used in humans and species with similar size eyes. Tonometers with tips with biprism ...