Numerical Simulation of the blood flow behavior in the circle of  Willis

نویسندگان

  • Seyyed Esmail Razavi
  • Rana Sahebjam
چکیده

INTRODUCTION This paper represents the numerical simulation of blood flow in the circle of Willis (CoW). Circle of Willis is responsible for the oxygenated blood distribution into the cerebral mass. To investigate the blood behavior, two Newtonian and non-Newtonian viscosity models were considered and the results were compared under steady state conditions. METHODS Methodologically, the arterial geometry was obtained using 3D magnetic resonance angiography (MRA) data. The blood flow through the cerebral vasculature was considered to be steady and laminar, and the Galerkin's finite element method was applied to solve the systems of non-linear Navier-Stokes equations. RESULTS Flow patterns including flow rates and shear rates were obtained through the simulation. The minimal magnitude of shear rates was much greater than 100 s(-1) through the larger arteries; thus, the non-Newtonian blood viscosity tended to approach the constant limit of infinite shear viscosity through the CoW. So, in larger arteries the non-Newtonian nature of blood was less dominant and it would be treated as a Newtonian fluid. The only exception was the anterior communicating artery (ACoA) in which the blood flow showed different behavior for the Newtonian and non-Newtonian cases. Conclusion By comparing the results it was concluded that the Newtonian viscosity assumption of blood flow through the healthy, complete circle of Willis under the normal and steady conditions would be acceptably accurate.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Anatomical Variations of Circle of Willis in 57 Human Brains

Purpose: The circle of willis is responsible for blood supply of brain, which may suffer from anatomical variations. These disturbances can lead to aneurysm or even arterial rupture. The purpose of this study was to evaluate the anatomical structure of the cerebral arteries forming the circle of willis in adult cadavers. Also, cerebral versus non- cerebral versus non-cerebral arterial walls wer...

متن کامل

Numerical Simulation of the Wake Flow Behind an Ellipse using Random Vortex Method (RESEARCH NOTE)

Direct numerical simulation of the wake flow around and behind a planar ellipse using a random vortex method is presented. Fluid is considered incompressible and the aspect ratios of ellipse and the angles of attacks are varied. This geometry can be a logical prelude to the more complex geometries, but less time dependent experimental measurements are available to validate the numerical results...

متن کامل

بررسی واریاسیونهای آناتومیک حلقه عروقی مغز(حلقه ویلیس) از طریق آنژیوگرافی مغزی

ABSTRACT Anatomical variations have great importance among various medical disciplins. The significance of these variations differ from some points of view including system, site and degree of variation. Vascular system is a common site of variations. The importance of this system in supplying the organs, specially the brain has made it to be in focus for its variations. The main sourc...

متن کامل

Variations of the Circle of Willis in 100 Cadavers in Kerman Province

Background & Aims: The relationship between variations of Willis circle and some cerebrovascular diseases has been shown in previous studies. A few studies have been conducted in Iran on these variations. Methods: This study was performed on 100 recently deceased Iranians due to car accidents who had been referred to Kerman Forensic Medicine Center for autopsy. The length and diameter of cerebr...

متن کامل

Modeling the Circle of Willis Using Electrical Analogy Method under both Normal and Pathological Circumstances

Background and objective: The circle of Willis (COW) supports adequate blood supply to the brain. The cardiovascular system, in the current study, is modeled using an equivalent electronic system focusing on the COW.Method: In our previous study we used 42 compartments to model whole car- diovascular system. In the current study, nevertheless, we extended our model by using 63 compartments to m...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره 4  شماره 

صفحات  -

تاریخ انتشار 2014