Feasibility of Uranium Concentration Measurements for H Canyon Tank 16.7
نویسندگان
چکیده
SRTC evaluated the feasibility of using the H Canyon on-line diode array spectrophotometer to measure uranium concentrations in Tank 16.7. On-line measurements will allow an increase in highly enriched uranium (HEU) production by removing delays associated with off-line measurements. The instrument must be able to measure uranium at concentrations below 1.0 g/L with an uncertainty no greater than 0.3 g/L. SRTC determined that the system has a limit of quantitation of 0.15 g/L. At concentrations of 0.5 and 1.0 g/L, the spectrometer uncertainty is 0.10 g/L. No design changes, such as an increase in flow cell pathlength, are required to obtain this performance. Expected levels of iron in Tank 16.7 solutions will not interfere with the measurement. The CHEMCHEK method should not be used for confirmatory analysis, as it contributes excessively to the overall uncertainty of the measurement. SRTC expects that the spectrophotometer will meet the measurement requirements for Tank 16.7. WSRC-TR-2002-00568 v TABLE OF CONTENTS ABSTRACT...................................................................................................................... iv TABLE OF CONTENTS.................................................................................................. v LIST OF FIGURES ......................................................................................................... vi LIST OF TABLES ........................................................................................................... vi 1. SUMMARY................................................................................................................... 1 2. INTRODUCTION......................................................................................................... 1 2.1 Scope ................................................................................................................... 1 2.2 Spectrophotometer............................................................................................ 1 2.3 Study ................................................................................................................... 3 3. EXPERIMENTAL METHODS................................................................................... 3 3.1 Uranium prediction models .............................................................................. 3 3.2 Test spectra ........................................................................................................ 5 4. RESULTS ................................................................................................................. 5 5. DISCUSSION........................................................................................................... 8 6. CONCLUSIONS...................................................................................................... 9 7. ACKNOWLDGEMENTS..................................................................................... 10 8. REFERENCES........................................................................................................... 10 WSRC-TR-2002-00568 vi LIST OF FIGURES Figure 1. Schematic diagram of spectrophotometer system. ........................................2 Figure 2. Spectra of low uranium solutions....................................................................6 Figure 3. Spectra of iron-bearing solutions....................................................................7 Figure 4. Spectra of low uranium solutions in H Canyon. ............................................8 Figure 5. Uranium model uncertainty as a function of concentration. ......................10 LIST OF TABLES Table 1. SRTC and H Canyon uranium prediction models..........................................5 Table 2. Prediction of low uranium solutions.................................................................6 Table 3. Measurements of low uranium calibration solutions in H Canyon. ..............8 Table 4. Estimated spectrometer uncertainties............................................................10 WSRC-TR-2002-00568 1
منابع مشابه
Measurements of natural uranium concentration in Caspian Sea and Persian Gulf water in by laser flourimetric method
ABSTRACT Background : Natural uranium exists in earth crust and seawater. The concentration of uranium might increase by human manipulation or geological changes. The aim of this study was to verify susceptibility of laser flourimetry method to determine the uranium concentration in Caspian Sea and Persian Gulf water. Materials and Methods : Laser flourimetric method was used to determine...
متن کاملResidence time of groundwater issuing from the South Rim Aquifer in the eastern Grand Canyon
In the eastern Grand Canyon, secondary porosity created by north trending faults, folds, and breccia pipes, facilitates groundwater flow through the South Rim carbonate aquifer. Springs associated with the South Rim Aquifer have low H concentrations, [Ca']/[Mg '] ratios close to unity, and variable uranium concentrations. For a geochemical comparison, springs are subcategorized on the basis of ...
متن کاملApplying GIS in Characterizing and Modeling Contaminant Transport in Surface Water at Los Alamos National Laboratory
At Los Alamos National Laboratory, transport of uranium and other metals away from firing sites is evaluated through the employment of GIS techniques. These techniques are demonstrated through three hydrologic examples: (1) design of a contaminant sampling scheme in an unknown watershed; (2) characterization of the spatial variability of uranium and copper; and (3) modeling uranium transport aw...
متن کاملA survey of natural uranium concentrations in drinking water supplies in Iran
Background: Measurement of back ground concentration of uranium in drinking water is very important for many reasons, specially, for human health. The uranium concentration in drinking water in many counties is a matter of concern for clinical and radioactive poisoning. Materials and Methods: The uranium concentration in drinking water is determined using laser flourimatric uranium analyzer. Fo...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2002