Contamination of syringe plungers during the sampling of cyclophosphamide solutions.
نویسندگان
چکیده
The presence of cytotoxic agents in the urine of operators and in their environment has been demonstrated. The pharmacokinetics of the urinary elimination of cyclophosphamide suggests that these drugs are absorbed cutaneously during handling. In the framework of a more general study on the contamination of hospital environment, the present study addresses the possible presence of cytotoxic agents on the plungers of syringes. The report is based on results indicating that the bacterial contamination of a plunger may result in the contamination of the solution being sampled. The study was divided into two phases. The first phase consisted in measuring the contamination of the plungers of eight syringes used for handling cyclophosphamide. Cyclophosphamide was analysed by gas chromatography-mass spectrometry with a detection limit of 0.1 ng/ml. The aim of the second phase was to localize the contamination on the plunger and thus determine the amount of drug that comes into contact with the gloves of the operators. The contamination was quantified by measuring the activity of metastable technetium. The results of the first phase showed that all the plungers were contaminated with cyclophosphamide amounts varying from 3.7 to 445.7 ng. The second phase showed that the infiltration of liquid onto the plunger depended on the solution being sampled. Almost no infiltration was seen with labelled water, but contamination appeared after the first sampling of a cyclophosphamide solution, then increased as a function of the number of times the plunger was pushed in and out. These results indicate that cyclophosphamide solutions infiltrate onto the plungers of syringes. They suggest that the general procedure for handling cytotoxic agents should be modified, and a regular replacement of syringes should be enforced. They also partly explain why the gloves of 50-90% operators are contaminated after a single preparation. The contamination seems to depend on the type of solution sampled and the number of samplings. Initial investigations by the manufacturer of the syringes had shown that the acid pH of cyclophosphamide solutions may affect the lubricant of the joint. Our study demonstrates that the contamination of plungers is one of the sources of environmental contamination for health workers handling antineoplastic agents, even in the absence of manipulation errors. More generally, these results demonstrate that the exposure of operators cannot be clearly described unless all existing sources of contamination in their environment are identified. The implementation of suitable procedures should thus take into account all possible sources of contamination, including technical facilities such as the use of a safety cabinet or an isolator.
منابع مشابه
Syringe plunger contamination by hazardous drugs: a comparative study.
AIM The purpose of this study was to perform a comparative cyclophosphamide contamination level test with Becton Dickinson® syringe plungers with Phaseal® Closed System Transfer Devices and Equashield® syringe plungers under routine oncological compounding conditions. METHOD The ChemoGlo™ sampling kit and analysis services were used to test for cyclophosphamide contamination levels on the syr...
متن کاملComparative Study of Syringe Contamination by Hazardous Drugs
Aim e purpose of this study was to compare surface contamination resulting from standard syringe plungers and cylinders compared to using the EQUASHIELD® Syringe Unit. Method e contamination level of standard syringes was compared to that of EQUASHIELD® Syringe Units, after repeated pharmaceutical manipulations using an antineoplastic (Cyclophosphamide) drug. Results Signi cant levels of up to ...
متن کاملبررسی نتایج استفاده مجدد از سرنگهای یک بار مصرف انسولین در بیماران وابسته به انسولین مراجعه کننده به درمانگاه شهید مطهری شیراز
Background: In spite of a high risk of infection, multiple usages of disposable insulin syringes among diabetic patients is quite common. The present study was designed to assess the outcome of multiple usages of disposable insulin syringes in insulin dependent patients referring to Shahid Motahari clinic in Shiraz . Materials and methods: For this descriptive study, through a random sampling m...
متن کاملBiological Monitoring of Healthcare Workers Exposed to Antineoplastic Drugs: Urinary Assessment of Cyclophosphamide and Ifosfamide
Exposure of health care workers to antineoplastic drugs and subsequent adverse health effects is still an open issue. Very little has been studied on the extent of occupational exposure and handling conditions of antineoplastic drugs in Iran. We aimed to determine cyclophosphamide and ifosfamide concentrations in the urine samples of oncology healthcare workers. In addition, we assessed workpla...
متن کاملBiological Monitoring of Healthcare Workers Exposed to Antineoplastic Drugs: Urinary Assessment of Cyclophosphamide and Ifosfamide
Exposure of health care workers to antineoplastic drugs and subsequent adverse health effects is still an open issue. Very little has been studied on the extent of occupational exposure and handling conditions of antineoplastic drugs in Iran. We aimed to determine cyclophosphamide and ifosfamide concentrations in the urine samples of oncology healthcare workers. In addition, we assessed workpla...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of oncology pharmacy practice : official publication of the International Society of Oncology Pharmacy Practitioners
دوره 11 1 شماره
صفحات -
تاریخ انتشار 2005