Determination of Actinide Elements in Environmental Samples by Icp-ms

نویسندگان

  • Jason Bedford Truscott
  • Roger Doney Truscott
چکیده

DETERMINATION OF ACTINDE ELEMENTS iN ENVIRONMENTAL SAMPLES BY ICP-MS Jason Bedford Truscott Methods for the determination of the actinide elements m water, biological, soil and sediment samples have been developed usmg on-line sohd phase extraction and high performance liquid chromatography (I{PLC) coupled with mductively coupled plasma mass spectrometry (ICP-MS) Initial applications utilised a commercially available resm, namely TRU-Spec resin, for efficient removal of the matrix pnor to elution of uranium and thorium analytes Comparative analyses of reference matenals and natural water samples from Plymouth and Dartmoor demonstrated significant improvement m precision and speed of analysis by using TRU-Spec coupled to ICPMS compared with alpha spectrometry. Further applications of the TRU-Spec resin for the determination of the transuranic actinide elements neptunium, plutonium and americium, resulted m the successful determination of Pu and 7Np in biological reference matenals Detection limits were 700, 850, and 600 attograms (ag) for 7Np, Pu, and 241Am, respectively, for a 0 5 ml sample injection, and better than 200 ag g 4 with 50 ml pre-concentration when sector field (SF) ICP-MS was used A method for the selective sequential elution of uranium and plutonium was also developed to facilitate the determination of Pu without interference due to the 8U'H polyatomic ion, caused by high concentrations of 8U in sediment samples Investigations were performed into the use of a polymeric substrate, which was dynamically coated with chelating dyes such as xylenol orange and 4-(2-pyndylazo) resorcmol, and a silica substrate coated with permanently bonded iminodiacetic acid The latter was used for the successful determination of uranium and thorium in certified reference matenal waters However, the column was found to have a high affinity for iron, makIng it unsuitable for the determination of the actinides in soil and sediment samples Subsequently, a polystyrene substrate which was dynamically coated with dipicolmic acid was used for HPLC coupled with SF-ICP-MS Using this column it was possible to separate the various actinides from each other and from the matnx In particular, it was possible to separate plutonium and uranium to facilitate interference-free determination of the former. The column also exhibited some selectivity for different oxidation states of Np, Pu and U Two oxidation states each for plutonium and neptunium were found, tentatively identified as Np(V) and Pu(ffl) elutmg at the solvent front, and Np(IV) and Pu(IV) eluting much later Detection limits were 12, 8, and 4 fg for 7Np, Pu, and 241Am, respectively, for a 0 5 ml injection, and the system was successfully used for the determination of Pu in water, biological and soil reference materials

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

RoHS/ELV Directives - Measurement of Heavy Metals Using ICP-MS Application

This application note describes a robust analytical method for the determination of heavy metals and substances regulated by the EU Restriction of Hazardous Substances/End of Life Vehicles (RoHS/ELV) directives. Based on the experience of Nihon Environmental Services Co., Ltd in Japan using an Agilent Technologies 7500c ORS (Octopole Reaction System) collision/reaction cell ICP-MS, this note su...

متن کامل

Application of Inductively Coupled Plasma Mass the Measurement of Long-Lived Radionuclides in Samples

This review describes applications of inductively coupled plasma mass spectrometry (ICP-MS) to the determination of long-lived radionuclides in environmental samples. Simultaneous determination of 232Th and 238U in biological samples is described in detail; in this procedure an internal standard, Tl or Bi, is adopted for correction of the matrix effect. Determination of 237Np in soil samples by...

متن کامل

Rapid and Reliable Routine Analysis of Urine by Octopole Reaction Cell ICP-MS Application

The Agilent 7500c Inductively Coupled Plasma Mass Spectrometer (ICP-MS) was used for the fast, routine, and reliable analysis of 23 trace elements in urine. The complete method validation for all elements is described, including the evaluation of short-term and long-term stability, the analysis of different reference materials and the discussion of precision and accuracy in internal and externa...

متن کامل

Determination of I/I isotope ratios in liquid solutions and environmental soil samples by ICP-MS with hexapole collision cell

The determination of I in environmental samples at ultratrace levels is very difficult by ICP-MS due to a high noise caused by Xe impurities in argon plasma gas (interference of Xe), possible IH2 1 interference and an insufficient abundance ratio sensitivity of the ICP mass spectrometer for I/I isotope ratio measurement. A sensitive, powerful and fast analytical technique for iodine isotope rat...

متن کامل

Rapid and Reliable Routine Analysis of Urine by Octopole Reaction Cell ICP-MS Application

The Agilent 7500c Inductively Coupled Plasma Mass Spectrometer (ICP-MS) was used for the fast, routine, and reliable analysis of 23 trace elements in urine. The complete method validation for all elements is described, including the evaluation of short-term and long-term stability, the analysis of different reference materials and the discussion of precision and accuracy in internal and externa...

متن کامل