Paw-dragging: a novel, sensitive analysis of the mouse cylinder test.

نویسندگان

  • R Brian Roome
  • Jacqueline L Vanderluit
چکیده

The cylinder test is routinely used to predict focal ischemic damage to the forelimb motor cortex in rodents. When placed in the cylinder, rodents explore by rearing and touching the walls of the cylinder with their forelimb paws for postural support. Following ischemic injury to the forelimb sensorimotor cortex, rats rely more heavily on their unaffected forelimb paw for postural support resulting in fewer touches with their affected paw which is termed forelimb asymmetry. In contrast, focal ischemic damage in the mouse brain fails to result in comparable consistent deficits in forelimb asymmetry. While forelimb asymmetry deficits are infrequently observed, mice do demonstrate a novel behaviour post stroke termed "paw-dragging". Paw-dragging is the tendency for a mouse to drag its affected paw along the cylinder wall rather than directly push off from the wall when dismounting from a rear to a four-legged stance. We have previously demonstrated that paw-dragging behaviour is highly sensitive to small cortical ischemic injuries to the forelimb motor cortex. Here we provide a detailed protocol for paw-dragging analysis. We define what a paw-drag is and demonstrate how to quantify paw-dragging behaviour. The cylinder test is a simple and inexpensive test to administer and does not require pre-training or food deprivation strategies. In using paw-dragging analysis with the cylinder test, it fills a niche for predicting cortical ischemic injuries such as photothrombosis and Endothelin-1 (ET-1)-induced ischemia--two models that are ever-increasing in popularity and produce smaller focal injuries than middle cerebral artery occlusion. Finally, measuring paw-dragging behaviour in the cylinder test will allow studies of functional recovery after cortical injury using a wide cohort of transgenic mouse strains where previous forelimb asymmetry analysis has failed to detect consistent deficits.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Heat Transfer Enhancement of a Flat Plate Boundary Layer Distributed by a Square Cylinder: Particle Image Velocimetry and Temperature-Sensitive Paint Measurements and Proper Orthogonal Decomposition Analysis

The current empirical study was conducted to investigate the wall neighborhood impact on the two-dimensional flow structure and heat transfer enhancement behind a square cylinder. The low- velocity open-circle wind tunnel was used to carry out the study tests considering the cylinder diameter (D)-based Reynolds number (ReD) of 5130. The selected items to compare were different gap he...

متن کامل

Thermo-elastic Analysis of Functionally Graded Thick- Walled Cylinder with Novel Temperature – Dependent Material Properties using Perturbation Technique

In this work, thermo – elastic analysis for functionally graded thick – walled cylinder with temperature - dependent material properties at steady condition is carried out. The length of cylinder is infinite and loading is consist of internal hydrostatic pressure and temperature gradient. All of physical and mechanical properties expect the Poisson's ratio are considered as multiplied an expone...

متن کامل

Low Cycle Fatigue Simulation of Valve Bridge Region in Cylinder Head Based on Critical Plane Model

The reason of this study is low cycle failure of cast iron cylinder head during the E5 standard durability test. The goal of the present investigation is durability test simulation and low cycle fatigue life evaluation of cast iron cylinder head. With uncouple structural analysis, preloads, thermal and mechanical load and boundary conditions are prescribed to finite element model of the cylinde...

متن کامل

The thermal probe test: A novel behavioral assay to quantify thermal paw withdrawal thresholds in mice

Rodent models are frequently used to improve our understanding of the molecular mechanisms of pain and to develop novel analgesics. Robust behavioral assays that quantify nociceptive responses to different sensory modalities, such has heat, are therefore needed. Here, we describe a novel behavioral assay to quantify thermal paw withdrawal thresholds in mice, called the thermal probe test, and c...

متن کامل

A novel hot-plate test sensitive to hyperalgesic stimuli and non-opioid analgesics.

It is widely accepted that the classical constant-temperature hot-plate test is insensitive to cyclooxygenase inhibitors. In the current study, we developed a variant of the hot-plate test procedure (modified hot-plate (MHP) test) to measure inflammatory nociception in freely moving rats and mice. Following left and right hind paw stimulation with a phlogogen and vehicle, respectively, the anim...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of visualized experiments : JoVE

دوره 98  شماره 

صفحات  -

تاریخ انتشار 2015