Assessment of Choroidal Thickness in Healthy and Glaucomatous Eyes Using Swept Source Optical Coherence Tomography

نویسندگان

  • Chunwei Zhang
  • Andrew J. Tatham
  • Felipe A. Medeiros
  • Linda M. Zangwill
  • Zhiyong Yang
  • Robert N. Weinreb
  • Andreas Wedrich
چکیده

PURPOSE To evaluate choroidal thickness (CT) in healthy and glaucomatous eyes using Swept Source Optical Coherence Tomography (SS-OCT). METHODS A cross-sectional observational study of 216 eyes of 140 subjects with glaucoma and 106 eyes of 67 healthy subjects enrolled in the Diagnostic Innovations in Glaucoma Study. CT was assessed from wide-field (12×9 mm) SS-OCT scans. The association between CT and potential confounding variables including age, gender, axial length, intraocular pressure, central corneal thickness and ocular perfusion pressure was examined using univariable and multivariable regression analyses. RESULTS Overall CT was thinner in glaucomatous eyes with a mean (± standard deviation) of 157.7±48.5 µm in glaucoma compared to 179.9±36.1 µm in healthy eyes (P<0.001). The choroid was thinner in both the peripapillary and macular regions in glaucoma compared to controls. Mean peripapillary CT was 154.1±44.1 µm and 134.0±56.9 µm (P<0.001) and macular CT 199.3±46.1 µm and 176.2±57.5 µm (P<0.001) for healthy and glaucomatous eyes respectively. However, older age (P<0.001) and longer axial length (P<0.001) were also associated with thinner choroid and when differences in age and axial length between glaucomatous and healthy subjects were accounted for, glaucoma was not significantly associated with CT. There was also no association between glaucoma severity and CT. CONCLUSIONS Glaucoma was not associated with CT measured using SS-OCT; however, older age and longer axial length were associated with thinner choroid so should be considered when interpreting CT measurements.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Analysis of Age-related Choroidal Layers Thinning in Healthy Eyes Using Swept-source Optical Coherence Tomography.

PURPOSE To study the changes in the choroidal layers thickness with age in a healthy population using swept-source optical coherence tomography. METHODS Retrospective data analysis of a subgroup of eyes from a previous single-center, prospective, cross-sectional, noninterventional study. One hundred and sixty-nine healthy eyes were evaluated using swept-source optical coherence tomography. In...

متن کامل

Comparison of Choroidal Thickness in Psoriasis and Control Groups Using Optical Coherence Tomography

Background and Objective: One of the most common extracutaneous complications in psoriasis patients is ocular complications, which is controversial concerning its effect on choroidal thickness. This study aimed to compare the psoriasis patients with healthy individuals in terms of the thickness of the choroidal layer using the optical coherence tomography technique. Materials and Methods: In t...

متن کامل

Retinal Nerve Fiber Layer Thickness Measurement Comparison Using Spectral Domain and Swept Source Optical Coherence Tomography.

PURPOSE To investigate the retinal nerve fiber layer (RNFL) thickness concordance when measured by spectral domain (SD) and swept source (SS) optical coherence tomography (OCT), and to compare glaucoma-discriminating capability. METHODS RNFL thicknesses were measured with the scan circle, centered on the optic nerve head, in 55 healthy, 41 glaucoma suspected, and 87 glaucomatous eyes. The RNF...

متن کامل

Correlation of Aging and Segmental Choroidal Thickness Measurement using Swept Source Optical Coherence Tomography in Healthy Eyes

PURPOSE To assess and compare choroidal thickness changes related to aging, we determined whether changes are due to thinning of the choriocapillaris plus Sattler's (CS) layer and/or the large vessel layer in healthy eyes using swept-source optical coherence tomography (SS-OCT) at a wavelength of 1,050-nm. METHODS We studied 115 normal eyes of 115 healthy volunteers, all with refractive error...

متن کامل

Choroidal thickness measured using swept-source optical coherence tomography is reduced in patients with type 2 diabetes

OBJECTIVE To compare choroidal thickness between patients with type 2 diabetes (T2D) and healthy controls measured using swept-source optical coherence tomography (SS-OCT). METHODS The sample comprised 157 eyes of 94 T2D patients, 48 eyes of which had diabetic macular edema (DME), and 71 normal eyes of 38 healthy patients. Subfoveal (SF) choroidal thickness, and choroidal thickness at 500-μm ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره 9  شماره 

صفحات  -

تاریخ انتشار 2014