Reliability of Echocardiography Measurement of Patent Ductus Arteriosus Minimum Diameter: A Meta-analysis

نویسندگان

  • Yong-quan Huang
  • Yin Huang
  • Dan Huang
  • Mao
  • Li-yun Luo
  • Jian Chen
چکیده

Objective: To systematically evaluate the reliability of transthoracic echocardiographic (TTE) measurements of the narrowest diameter in patients with patent ductus arteriosus (PDA) in comparison to angiographic measurements. Methods: We searched articles published between January 1990 to August 2015 that compared diameters of PDA both measured by TTE and angiography in PubMed, Cochrane Library, Wanfang Data database, and CNKI. Two researchers screened the literature, extracted data and assess the quality independently. Weighted mean difference (WMD) and 95% confidence intervals (95% CI) were calculated, heterogeneity was evaluated, and publication bias was estimated. The correlation coefficients of the narrowest PDA diameter measured by echocardiography and angiography were merged by RevMan 5.2 and Stata 12.0 software. Results: 11 articles involving 870 patients are included. Meta-analysis demonstrated that measurement values of the minimum inner diameter by TTE were greater compared to angiography measurements (WMD = 0.86,95% CI: 0.71 ~ 1.02, P <0.001). Echocardiographic and angiographic measurements correlated closely with each other (R = 0.75,95% CI: 0.52 ~ 0.97). There was no evidence of publication bias. Conclusions Measurement of the minimum inner diameter of PDA by TTE has value for both the selection of therapeutic strategy and the PDA occluder model. Nevertheless, echocardiography overestimates minimum diameter in comparison to angiography.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Patent ductus arteriosus in a lamb: A case report

Patent ductus arteriosus (PDA) is a persistent patency of a vessel normally present in the fetus that connects the pulmonary arterial system to the aorta. The ductus arteriosus fails to close at birth when breathing commences and placental blood circulation is removed. Closure of the ductus arteriosus arises in response to decline pulmonary vascular resistance and increased systemic vascular re...

متن کامل

The Effect of Oral Ibuprofen on Closure of Patent Ductus Arteriosus in Term Neonates: A Clinical Trial Study

Background The function of ductus arteriosus closes within a few minutes to a few days after birth in term neonates. In some cases, the duct remains open after birth, a condition which is called patent ductus arteriosus (PDA). PDA is associated with high rates of neonatal mortality and morbidity. The present study aims to evaluate the effect of...

متن کامل

[Echocardiographic post-neonatal progress of preterm neonates with patent ductus arteriosus].

OBJECTIVE To identify clinical and echocardiography predictors of the spontaneous closure of patent ductus arteriosus in preterm neonates. METHODS Sixty-one consecutive preterm neonates (gestational age 30+/-2 weeks, birth weight 1.2+/-0.2 kg) were evaluated by echocardiogram on their third day of life and those with patent ductus arteriosus were selected for a prospective cohort. Echocardiog...

متن کامل

C-reactive protein and Platelets changes in preterm neonates with patent Ductus Arteriosus

Introduction: This study aimed to investigate CRP and platelet count changes in preterm neonates with Patent Ductus Arteriosus on the seventh day of birth compared to the third day. Methods: This longitudinal study was conducted on fifty neonates with PDA complications in Afzalipour hospital in 2017-2018. All neonates underwent repeated e...

متن کامل

Intravenous Paracetamol and Patent Ductus Arteriosus Closure

Background: Standard medical treatments for patent ductus arteriosus (PDA) closure are, including indomethacin/ibuprofen and surgical ligation. Nowadays, a new strategy to close PDA is the use of paracetamol. The present study aimed to describe the use of intravenous (IV) paracetamol for PDA closure in neonates who present a contraindication to ibuprofen or ibuprofen failure with no possibility...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2016