Simultaneous multianalyte ELISA performed on a microarray platform.
نویسندگان
چکیده
BACKGROUND A logical progression of the widely used microtiter plate ELISA is toward a protein array format that allows simultaneous detection of multiple analytes at multiple array addresses within a single well. Here we describe the construction and use of such a multiplex ELISA to measure prostate-specific antigen (PSA), alpha1-antichymotrypsin-bound PSA (PSA-ACT), and interleukin-6 (IL-6). METHODS We silanized glass plates and printed the appropriate capture antibodies to allow for the construction of "sandwich" ELISA quantification assays. We examined specificity of the assay for appropriate antigen, assembled calibration curves, and obtained PSA concentrations for 14 human serum samples. We compared the serum PSA concentrations derived through the use of our array with values obtained independently using a standard ELISA method. RESULTS R2 values generated by our microarray for the PSA and PSA-ACT calibration curves were 0.989 and 0.979, respectively. Analyte concentrations used for the construction of these curves were 0.31-20 microg of protein/L of diluent. IL-6 calibration curve concentrations were 4.9-300 ng of IL-6/L of diluent. The R2 value for the IL-6 calibration curve was 0.983. The 14 human serum samples screened by this micro-ELISA technique for PSA concentrations generated a regression equation (linear) with a slope of 0.83 +/- 0.10 and intercept of 0.74 +/- 0.70 (R2 = 0.88). CONCLUSIONS Multiplexed ELISA arrays are a feasible option for analyte quantification in complex biologic samples.
منابع مشابه
Development of a multianalyte enzyme-linked immunosorbent assay for permethrin and aroclors and its implementation for analysis of soil/sediment and house dust extracts.
Development of a multianalyte enzyme-linked immunosorbent assay (ELISA) for detection of permethrin and aroclors 1248 or 1254 and implementation of the assay for analysis of soil/sediment samples are described. The feasibility of using the multianalyte ELISA to monitor aroclors 1254 and permethrin simultaneously was tested with permethrin and aroclor standards and with aroclor- and permethrin-c...
متن کاملArray biosensor for simultaneous identification of bacterial, viral, and protein analytes.
The array biosensor was fabricated to analyze multiple samples simultaneously for multiple analytes. The sensor utilized a standard sandwich immunoassay format: Antigen-specific "capture" antibodies were immobilized in a patterned array on the surface of a planar waveguide and bound analyte was subsequently detected using fluorescent tracer antibodies. This study describes the analysis of 126 b...
متن کاملA disposable multianalyte electrochemical immunosensor array for automated simultaneous determination of tumor markers.
BACKGROUND Automated and convenient multianalyte detection with high throughput is increasingly needed in clinical diagnosis. We developed a disposable 4-by-2 array for programmed simultaneous amperometric immunoassay of 4 tumor markers. METHODS We used a screen-printed technique, 1-step immobilization method, and flow injection technique. We immobilized carcinoembryonic antigen, alpha-fetopr...
متن کاملThe False Discovery Rate in Simultaneous Fisher and Adjusted Permutation Hypothesis Testing on Microarray Data
Background and Objectives: In recent years, new technologies have led to produce a large amount of data and in the field of biology, microarray technology has also dramatically developed. Meanwhile, the Fisher test is used to compare the control group with two or more experimental groups and also to detect the differentially expressed genes. In this study, the false discovery rate was investiga...
متن کاملDevelopment and Validation of Protein Microarray Technology for Simultaneous Inflammatory Mediator Detection in Human Sera
Biomarkers, including cytokines, can help in the diagnosis, prognosis, and prediction of treatment response across a wide range of disease settings. Consequently, the recent emergence of protein microarray technology, which is able to quantify a range of inflammatory mediators in a large number of samples simultaneously, has become highly desirable. However, the cost of commercial systems remai...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 47 8 شماره
صفحات -
تاریخ انتشار 2001