The risk of translaminar screw fixation to the transverse foramen of the lower cervical spine: a computed tomography study
نویسندگان
چکیده
Translaminar screw fixation (TSF) of the axis is considered as an efficient, safe and simple surgical procedure, however the study of the potential risk of TSF to the transverse foramen in lower cervical spine is lacked. Head-neck CT images of 60 patients were included in this study. Maximum screw length, laminar thickness, the screw angle and the laminar height were measured. The feasibility of 3.5-mm diameter screw fixation and the potential risk of transverse foramen injury was analyzed. The TSF was safe at C3 and C4, but risky to the transverse foraman at a rate of 8.7% at C5 (0% on the left side and 20% on the right side), 33.3% at C6 (24.4% on the left side and 42.9% on the right side). C7 had the highest 77.8% rate (65.5% on the left side and 89.8% on the right side). The safe screw length was 27.7 mm at C3, 27.4 mm at C4, 28.0 mm at C5, 25.6 mm at C6 and 25.5 mm at C7, respectively. The present study showed that translaminar screw could place the transverse foramen of C5-C7 at risk. Preoperative CT scanning was necessary for safe screw placement.
منابع مشابه
Predicting Unilateral Postlaminectomy C5 Palsy by Measuring C5 Exit Foramen Area on Preoperative Computed Tomography
Background. Postoperative C5 motor palsy is known as a common complication not only after cervical laminectomy but also after anterior discectomy. There is no consensus to verify any of the proposed mechanisms of C5 palsy following posterior cervical decompression. The authors of this article have found that C5 palsy is more common among patients with smaller C5 root exit foramen area. The purp...
متن کاملC2 Anatomy for Translaminar Screw Placement Based on Computerized Tomographic Measurements
STUDY DESIGN Anatomical study. PURPOSE To evaluate the anatomy of the C2 lamina for translaminar screw placement based on computerized tomographic measurements. OVERVIEW OF LITERATURE C2 translaminar screw insertion is a novel technique for atlanto-axial fixation. The risk of vertebral artery injury can be decreased by this technique. However, a large series of anatomical studies on C2 anat...
متن کاملCT-based morphometric analysis of C1 laminar dimensions: C1 translaminar screw fixation is a feasible technique for salvage of atlantoaxial fusions
BACKGROUND Translaminar screw fixation has become an alternative in the fixation of the axial and subaxial cervical spine. We report utilization of this approach in the atlas as a salvage technique for atlantoaxial stabilization when C1 lateral mass screws are precluded. To assess the feasibility of translaminar fixation at the atlas, we have characterized the dimensions of the C1 lamina in the...
متن کاملAccuracy Assessment of Freehand Pedicular Screw Placement
Background: The purpose of this prospective study was to determine the accuracy of pedicular screw insertion withoutthe use of fluoroscopy.Methods: This study was conducted on patients with spinal diseases in need of pedicular screw fixation and fusion.The included patients suffered from such conditions as vertebral fracture, spinal stenosis, kyphosis, tumor, and pelvicf...
متن کاملPosterior atlantoaxial fusion using a C2 transverse foramen-penetrating screw: A technical note
Background Although recent development of screw instrumentation techniques for rigid fixation of the atlantoaxial joint has increased surgical options, patients in whom screws of any type cannot be safely placed are sometimes encountered. We present a unique surgical technique for C1-2 transarticular screw placement utilizing a novel trajectory. Methods A 35-year-old male with a history of Do...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2017