OBJECTIVE The aim of this in-vitro study was to compare the tolerance of surgical instruments in surgical guides produced by 3-D printing, without metal sleeves to a surgical guide with conventional metal sleeves from two different manufacturers. MATERIALS AND METHODS Lateral movements of drill tips caused by tolerance between the sleeve and drill key and between the drill key and the drill were recorded after application of a standardized force to the surgical instruments. Four groups were tested: Control 1 (C1): metal sleeve from commercially available surgical system 1; Test 1 (T1): 3-D-printed sleeve for surgical system 1; Control 2 (C2): metal sleeve from commercially available surgical system 2. Test 2 (T2): 3-D-printed sleeve for surgical system 2. RESULTS The mean total lateral movement was 0.75 mm (0.5-1.04 mm) in the C1 group and 0.91 mm (0.54-1.34 mm) in the C2 group. The mean amount of movement from tolerance between sleeve and drill-guiding key was 0.31 mm (range 0.22-0.41 mm) in C1 and 0.42 mm (range 0.29-0.56 mm) in C2. This lateral movement was in mean reduced by 0.24 mm (32%) in T1 and by 0.39 mm (43%) in T2 group. This reduction was statistically significant in both groups (P < 0.001). CONCLUSION The tolerance of surgical instruments and the lateral movements of the drills were significantly reduced by the use of 3-D printing with reduced sleeve diameter. This reduction could improve the overall accuracy in computer-assisted template-guided implant dentistry. The lateral movement of the drill can be further reduced by using a shorter drill and a higher drill key. This can be considered during implant planning and CAD/CAM of surgical guides.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

مقدمه‌ای بر فناوری قرار دادن ایمپلنت به کمک کامپیوتر (Computer Guided Implantology)مروری بر مقالات، تاریخچه و مفاهیم اولیه

Surgical and prosthodontic implant complications are often the case of inadvertent improper diagnosis, planning, and placement. These complications always pose a significant challenge in implant dentistry. In this article, it is attempted to depict a new technique in which advanced software program along with newly developed CAD/CAM technology called rapid prototyping will be used. This technol...

متن کامل

Real-time motion tracking in image-guided oral implantology.

BACKGROUND As a crucial part of an image-guided oral implantology system (IGOIS), intra-operative motion tracking is important in terms of accuracy and efficiency. The tracking method, including the relevant algorithms, is described in detail. METHODS The conventional CAD method is proposed to build the three-dimensional (3D) surgical instrument models. With the application of the optical tra...

متن کامل

A Review on Titanium Nitride and Titanium Carbide Single and Multilayer Coatings Deposited by Plasma Assisted Chemical Vapor Deposition

In this paper, we reviewed researches about the titanium nitride (TiN) and titanium carbide (TiC) single and multilayer coatings. These coatings were deposited by the plasma assisted chemical vapor deposition (PACVD) technique. Plasma-based technologies are used for the processing of thin films and coatings for different applications such as automobile and aerospace parts, computer disc drives,...

متن کامل

The Future of Healthcare Facilities: How Technology and Medical Advances May Shape Hospitals of the Future

In this review article, we aim to depict how healthcare facilities may look in the near future from an architectural design point of view. For this purpose, we review newly introduced technology and medical advances in the field of healthcare, such as artificial intelligence (AI), robotic surgery, 3D printing, and information technology (IT), and suggest how those advances may affect the archit...

متن کامل

P-45: Predictive Value of Follicular Fluid VitaminD on Assisted Reproductive TechniqueOutcome

Background: Vitamin D, a steroid hormone, has critical roles in human health. The available data thus identify vitamin D as an important substance in processes involved in reproductive success and thereby suggest pathophysiological mechanisms for reproductive compromise in the setting of vitamin D deficiency. Realizing the prevalence of vitamin D insufficiency in our country, we hypothesized th...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Clinical oral implants research

دوره 26 3  شماره 

صفحات  -

تاریخ انتشار 2015