Relationship of late loss in lumen diameter to coronary restenosis in sirolimus-eluting stents.

نویسندگان

  • Laura Mauri
  • E John Orav
  • A James O'Malley
  • Jeffrey W Moses
  • Martin B Leon
  • David R Holmes
  • Paul S Teirstein
  • Joachim Schofer
  • Günter Breithardt
  • Donald E Cutlip
  • Dean J Kereiakes
  • Chunxue Shi
  • Brian G Firth
  • Dennis J Donohoe
  • Richard E Kuntz
چکیده

BACKGROUND Observed rates of restenosis after drug-eluting stenting are low (<10%). Identification of a reliable and powerful angiographic end point will be useful in future trials. METHODS AND RESULTS Late loss (postprocedural minimum lumen diameter minus 8-month minimum lumen diameter) was measured in the angiographic cohorts of the SIRIUS (n=703) and E-SIRIUS (n=308) trials. Two techniques, the standard normal approximation and an optimized power transformation, were used to predict binary angiographic restenosis rates and compare them with observed restenosis rates. The mean in-stent late loss observed in the SIRIUS trial was 0.17+/-0.45 mm (sirolimus) versus 1.00+/-0.70 mm (control). If a normal distribution was assumed, late loss accurately estimated in-stent binary angiographic restenosis for the control arm (predicted 35.4% versus observed 35.4%) but underestimated it in the sirolimus arm (predicted 0.6% versus observed 3.2%). Power transformation improved the reliability of the estimate in the sirolimus arm (predicted 3.2% [CI 1.0% to 6.7%]) with similar improvements in the E-SIRIUS trial (predicted 4.0% [CI 1.2% to 7.0%] versus observed 3.9%). In the sirolimus-eluting stent arm, in-stent late loss correlated better with target-lesion revascularization than in-segment late loss (c-statistic=0.915 versus 0.665). CONCLUSIONS Because distributions of late loss with a low mean are right-skewed, the use of a transformation improves the accuracy of predicting low binary restenosis rates. Late loss is monotonically correlated with the probability of restenosis and yields a more efficient estimate of the restenosis process in the era of lower binary restenosis rates.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Letter regarding article by Mauri et al, "Late loss in lumen diameter and binary restenosis for drug-eluting stent comparison".

BACKGROUND Published rates of coronary restenosis have fallen below 10% in drug-eluting stent trials. Early evaluations of new stents have used continuous end points that are presumed surrogates for restenosis, but the generalizability and power of such end points have not been examined systematically. METHODS AND RESULTS We examined the relationship between incremental changes in observed la...

متن کامل

Late Loss in Lumen Diameter and Binary Restenosis for Drug-Eluting Stent Comparison

Background—Published rates of coronary restenosis have fallen below 10% in drug-eluting stent trials. Early evaluations of new stents have used continuous end points that are presumed surrogates for restenosis, but the generalizability and power of such end points have not been examined systematically. Methods and Results—We examined the relationship between incremental changes in observed late...

متن کامل

Angiographic findings of the multicenter Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL): sirolimus-eluting stents inhibit restenosis irrespective of the vessel size.

BACKGROUND Restenosis remains the major limitation of coronary catheter-based intervention. In small vessels, the amount of neointimal tissue is disproportionately greater than the vessel caliber, resulting in higher restenosis rates. In the Randomized Study With the Sirolimus-Eluting Bx Velocity Balloon-Expandable Stent (RAVEL) trial, approximately 40% of the vessels were small (<2.5 mm). The ...

متن کامل

Quantitative assessment of angiographic restenosis after sirolimus-eluting stent implantation in native coronary arteries.

BACKGROUND Sirolimus-eluting stents (SESs) reduce angiographic restenosis in patients with focal, native coronary artery stenoses. This study evaluated the usefulness of SESs in complex native-vessel lesions at high risk for restenosis. METHODS AND RESULTS Angiographic follow-up at 240 days was obtained in 701 patients with long (15- to 25-mm) lesions in small-diameter (2.5- to 3.5-mm) native...

متن کامل

Randomized trial of paclitaxel- and sirolimus-eluting stents in small coronary vessels.

AIMS Sirolimus- and paclitaxel-eluting stents effectively reduce restenosis in small coronary vessels. The relative efficacy of these drug-eluting stents in this high-risk subset is not known. METHODS AND RESULTS A total of 360 patients undergoing percutaneous coronary intervention for de novo lesions in native coronary vessels with a diameter of <2.80 mm received randomly paclitaxel-eluting ...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:
  • Circulation

دوره 111 3  شماره 

صفحات  -

تاریخ انتشار 2005