Species measurements in the beam of an ionic liquid ferrofluid electrospray source

نویسندگان

  • Kurt J. Terhune
  • Michael L. Hause
  • Benjamin D. Prince
  • Nirmesh Jain
  • Brian S. Hawkett
چکیده

An ionic liquid ferrofluid (ILFF) using 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (EMIM-NTf2) as the carrier liquid was emitted from the peak formed via the Rosensweig instability and the electrospray beam was measured using quadrupole and TOF mass spectrometry. The Rosensweig instability peak source (RIPS) was found to operate in three stable emission current modes: transient-emission, lowcurrent, and high-current. Both quadrupole and linear TOF mass spectra for the final two modes were collected, and revealed that the charged-particle species within the electrospray beam varied between the two emission current modes. No correlation between the magnetic field strength and the collected mass spectra was measured. Mass flow measurements using a quartz crystal microbalance revealed that the RIPS only operated at a high mass flow rate of 3-5 ng/s during the startup transient-emission mode and otherwise ran at mass flow rates of 0.03-0.3 ng/s indicating the absence of droplet species during the majority of emission. The RIPS quadrupole mass spectra were compared to a pure ionic liquid needle source quadrupole spectra and it was discovered that multiple species exist in the ILFF electrospray that are attributed to fragments respective ion species, with some species partially comprised of fragments from the polymer used for steric stabilization of the nanoparticles; specifically the block that comprises the stabilization group, poly(N,N-dimethylacrylamide), and the end functionalizing group, CH3CHCOOH.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Species measurements in the beam of an ionic liquid ferrofluid capillary electrospray source under magnetic stress

Three solutions of an ionic liquid ferrofluid (ILFF) using 1-ethyl-3-methylimidazolium bis(trifluoromethylsulfonyl)imide (EMIM-NTf2) as the carrier liquid were emitted from a capillary electrospray source and the resulting beam was measured using a time-of-flight mass spectrometer (TOF-MS). The solutions had 3.04, 5.98, and 8.80 wt% iron oxide nanoparticles making them susceptible to magnetic f...

متن کامل

Ionic liquid ferrofluid electrospray with EMIM-NTf2 and ferrofluid mode studies with FerroTec EFH-1 in a non- uniform magnetic field

An electrospray ion source was operated using a newly designed ionic liquid ferrofluid based on the ionic liquid EMIM-NTf2. The magnetic properties of the fluid were exploited to create self-assembling array of peaks on the fluid surface, which were then amplified using an electric field, eventually causing ions to be emitted from the tip of each peak in the instability. A beam current of 72 mi...

متن کامل

Capillary Extraction of the Ionic Liquid [Bmim][DCA] for Variable Flow Rate Operations

The ionic liquid [Bmim][DCA] is a propellant candidate in a standalone electrospray thruster or in a dual-mode propulsion system consisting of a chemical system and an electrospray system. Since limited published data exists for [Bmim][DCA], the electrospray characteristics are relatively unknown. Emission testing of the ionic liquid has been conducted to characterize the [Bmim][DCA] electrospr...

متن کامل

Comparing Direct and Indirect Thrust Measurements from Passively Fed and Highly Ionic Electrospray Thrusters

Highly ionic beams of several hundred μA per cm 2 have been measured from porous glass ionic liquid electrospray sources fabricated using a conventional mill. The thrust output from three prototype devices, two emitting the ionic liquid EMI-Im and one emitting EMI-BF 4, was measured directly using a precise balance. Thrusts up to 50 μN were measured when emitting EMI-Im in a bipolar, alternatin...

متن کامل

Influences of porous reservoir Laplace pressure on emissions from passively fed ionic liquid electrospray sources

Articles you may be interested in Influence of ion source configuration and its operation parameters on the target sputtering and implantation process Rev. Multiply charged ion-induced secondary electron emission from metals relevant for laser ion source beam diagnostics Rev.

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2014