Determination of biological thiols by high-performance liquid chromatography following derivatization by ThioGlo maleimide reagents.

نویسندگان

  • N Ercal
  • P Yang
  • N Aykin
چکیده

The importance of thiols has stimulated the development of a number of methods for determining glutathione and other biologically significant thiols. Methods that are currently available, however have some limitations, such as being time consuming and complex. In the present study, a new high-performance liquid chromatography (HPLC) method for determining biological thiols was developed by using 9-Acetoxy-2-(4-(2,5-dihydro-2,5-dioxo-1H-pyrrol-1-yl)phenyl)-3-oxo-3H-naphtho[2,1-b]pyran (ThioGlo3) as a derivatizing agent. ThioGlo reacts selectively and rapidly with the thiols to yield fluorescent adducts which can be detected fluorimetrically (lambda(ex) = 365 nm, lambda(em) = 445 nm). The within-run coefficient of variation for glutathione (GSH) by this method ranges from 1.08 to 2.94% whereas the between-run coefficient of variation for GSH is 4.31-8.61%. For GSH, the detection limit is around 50 fmol and the GSH derivatives remain stable for 1 month, if kept at 4 degrees C. Results for GSSG and cysteine are also included. The ThioGlo method is compared to our previous method in which N-(1-pyrenyl)maleimide (NPM) is used to derivatize thiol-containing compounds. The present method offers various advantages over the currently accepted techniques, including speed and sensitivity.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Liquid chromatography analysis of N-(2-mercaptopropionyl)-glycine in biological samples by ThioGlo 3 derivatization.

N-(2-Mercaptopropionyl)-glycine (MPG) is a synthetic aminothiol antioxidant that is used in the treatment of cystinuria, rheumatoid arthritis, liver and skin disorders. Recent studies have shown that MPG can function as a chelating, cardioprotecting and a radioprotecting agent. Several other studies have shown that it may also act as a free radical scavenger because of its thiol group. Thiol-co...

متن کامل

Development of Benzofurazan−bearing Fluorescence Labeling Reagents for Separation and Detection in High−performance Liquid Chromatography

High−performance liquid chromatography (HPLC) coupled with various detection systems has been widely adopted for the analyses of various molecules in many research fields, such as biological, pharmaceutical, food, and environmental [1,2]. The widening use of HPLC in the last four decades seems to be due to the advances in instrumentation, column resins, detection systems, and data processing. H...

متن کامل

Determination of thiocyl in biological samples by liquid chromatography with ThioGlo 3 derivatization.

Thiocyl (sodium thiosalicylate) belongs to a salicylate group of drugs, thus it has analgesic, antipyretic and anti-inflammatory effects. It possesses metal chelating function because it also belongs to a thiol-containing group of compounds which are well-known chelators. The studies of our research group showed that thiocyl is a promising chelator of lead poisoning due to its antioxidant and m...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

High Performance Liquid Chromatography Coupled with Pre-column Derivatization for Determination of Oxidized Glutathione Level in Rats Exposed to Paraquat

Glutathione (GSH) is one of the most important antioxidants that plays an essential role in detoxification of reactive oxygen species (ROS) which oxidizes to glutathione disulfide (GSSG). Paraquat (PQ), awidely used herbicide, causes pulmonary injury with the productionof ROS. Excessive ROS accumulation as a consequence of PQ exposure are frequently targeted by GSH thereby oxidative stress lead...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of chromatography. B, Biomedical sciences and applications

دوره 753 2  شماره 

صفحات  -

تاریخ انتشار 2001