K-space Model of Motion Artifacts in Synthetic Transmit Ultrasound Imaging

نویسنده

  • Svetoslav Ivanov
چکیده

Synthetic transmit aperture (STA) imaging gives the possibility to acquire an image with only few emissions and is appealing for 3D ultrasound imaging. Even though the number of emissions is low, the change in position of the scatterers prohibits the coherent summations of ultrasound echoes and leads to distortions in the image. In order to develop motion compensation and/or velocity estimation algorithms a thorough and intuitive understanding of the nature of motion artifacts is needed. This paper proposes a simple 2D broad band model for STA images, based on the acquisition procedure and the beamformation algorithm. In STA imaging a single element transmits a cylindrical wave. All elements are used in receive, and by applying different delays a low resolution image (LRI) is beamformed. A Fourier relation exists between the aperture function and all points in the beamformed LRI. This relation is used to develop an approximation of the point spread function (PSF) of a LRI. It is shown that the PSF of LRIs obtained by transmitting with different elements can be viewed as rotated versions of each other. Summing several LRIs gives a high resolution image. The model approximates the PSF of a high resolution image as a sum of rotated PSFs of a single LRI. The approximation is validated with a Field II simulation. The model predicts and explains the motion artifacts, and gives an intuitive feeling of what would happen for different velocities.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Accelerating Magnetic Resonance Imaging through Compressed Sensing Theory in the Direction space-k

Magnetic Resonance Imaging (MRI) is a noninvasive imaging method widely used in medical diagnosis. Data in MRI are obtained line-by-line within the K-space, where there are usually a great number of such lines. For this reason, magnetic resonance imaging is slow. MRI can be accelerated through several methods such as parallel imaging and compressed sensing, where a fraction of the K-space lines...

متن کامل

Velocity estimation using recursive ultrasound imaging and spatially encoded signals

Previously we have presented a recursive beamforming algorithm for synthetic transmit aperture focusing. At every emission a beamformed low-resolution image is added to an existing high-resolution one, and the low-resolution image from the previous emission with the current active element is subtracted yielding a new frame at every pulse emission. In this paper the method is extended to blood v...

متن کامل

Assessment of simulated patient motion and its effect on myocardial perfusion SPECT using two reconstruction methods (Filtered Backprojection;FBP and Iterative method) [Persian]

Introduction: Motion of the patient during myocardial perfusion SPECT could potentially results in false perfusion defects. The effect of different reconstruction methods on these artifacts is not studied. Clarification of the relation between the extent, severity and duration of motion with the resultant artifacts may be helpful in designing special soft wares for motion correction. This...

متن کامل

Design, Evaluation and Prototyping of a New Robotic Mechanism for Ultrasound Imaging

This paper presents a new robotic mechanism for ultrasound imaging. The device is placed on a patient's body by an operator, and an ultrasound expert controls the motions of the device to obtain ultrasound images. The paper focuses on the robotic mechanism that performs ultrasound imaging. The design of the mechanism is based on two approaches to produce center of motion for an ultrasound probe...

متن کامل

Artifact reduction techniques in Cone Beam Computed Tomography (CBCT) imaging modality

Introduction: Cone beam computed tomography (CBCT) was introduced and became more common based on its low cost, fast image procedure rate and low radiation dose compared to CT. This imaging modality improved diagnostic and treatment-planning procedures by providing three-dimensional information with greatly reduced level of radiation dose compared to 2D dental imaging modalitie...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2017