Photoplethysmography: beyond the calculation of arterial oxygen saturation and heart rate.
نویسنده
چکیده
In this article, I examine the source of the photoplethysmograph (PPG), as well as methods of investigation, with an emphasize on amplitude, rhythm, and pulse analysis. The PPG waveform was first described in the 1930s. Although considered an interesting ancillary monitor, the "pulse waveform" never underwent intensive investigation. Its importance in clinical medicine was greatly increased with the introduction of the pulse oximeter into routine clinical care in the 1980s. Its waveform is now commonly displayed in the clinical setting. Active research efforts are beginning to demonstrate a utility beyond oxygen saturation and heart rate determination. Future trends are being heavily influenced by modern digital signal processing, which is allowing a re-examination of this ubiquitous waveform. Key to unlocking the potential of this waveform is an unfettered access to the raw signal, combined with standardization of its presentation, and methods of analysis. In the long run, we need to learn how to consistently quantify the characteristics of the PPG in such a way as to allow the results from research efforts be translated into clinically useful devices.
منابع مشابه
تأثیر ساکشن لوله داخل نای بر وضعیت همودینامیک واکسیژناسیون خون شریانی
Background and Aim: Intratracheal suctioning is a standard method of nursing care for intubated patients with the aim of cleaning airway for good oxygenation. The aim of this study was to evaluate the effects of intratracheal suctioning on blood pressure, heart rate, and arterial oxygen saturation. Materials and Methods: This was a semi-experimental research in which the patients admitted t...
متن کاملEffects of position on oxygen saturation and heart rate in very low birth weight neonates
Background: Desirable oxygenation of preterm newborns has particular importance, for this reason different methods have been proposed to improve oxygenation of the newborns; one of these methods is the newborns' position. The aim of this study was to determine the effect of the position of low birth weight neonates on arterial oxygen saturation and heart rate. Methods: This interventional st...
متن کاملComparing the Effect of Simple Filtration Hemodialysis and Ultrafiltration Hemodialysis on Arterial Oxygen Saturation and Blood Pressure in Chronic Dialysis
Background and purpose: Hypoxemia and hypotension are important complications of hemodialysis in patients with chronic renal failure that are linked to several factors, including the type of filters used. The aim of this study was to compare the effect of simple filtration hemodialysis and ultrafiltration hemodialysis on blood pressure and blood arterial oxygen level. Materials and methods: In...
متن کاملOn the Analysis of Fingertip Photoplethysmogram Signals
Photoplethysmography (PPG) is used to estimate the skin blood flow using infrared light. Researchers from different domains of science have become increasingly interested in PPG because of its advantages as non-invasive, inexpensive, and convenient diagnostic tool. Traditionally, it measures the oxygen saturation, blood pressure, cardiac output, and for assessing autonomic functions. Moreover, ...
متن کاملComparison of the effect of thiopental sodium-midazolam combination on the hemodynamic response between tracheal intubation and laryngeal mask airway insertion: A clinical trial study
Background and Aim: The purpose of this study was to compare the effect of thiopental sodium-midazolam combination on the stress response and hemodynamic changes between tracheal intubation and laryngeal mask airway insertion during airway management. Materials and Methods: In this clinical trial study, 70 patients ASA 1, 2 candidates for elective surgery were randomly divided into two groups o...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Anesthesia and analgesia
دوره 105 6 Suppl شماره
صفحات -
تاریخ انتشار 2007