Precision and interlaboratory reproducibility of measurements of the Miissbauer effect in minerals

ثبت نشده
چکیده

Although the technique of Mcissbauer spectroscopy is now 25-years old and widely used, little empirical work has been done to determine its accuracy in measurements on minerals. To solve this deficiency, two mineral standards (a grunerite and an almandine/andradite garnet mix) have been selected. Precision of the technique was measured through five different sets of experiments seeking to analyze the reproducibility of measurements on a single sample mount, on several identical mounts of the same sample, and on a set of mounts with different sample concentrations, run times, and background counts. The two mineral standards were analyzed by other scientists at seven different laboratories; their data were also fit by the MIT program. The standard deviation of multiple measurements on the MIT apparatus is better than 0.016 mm./sec for isomer shift, 0.060 mm/sec or better for quadrupole splitting, and l.02Vo on individual peak area data. The standard deviation of interlaboratory measurements on the same minerals is slightly better because only ideal run conditions were used: 0.006 mm/sec for isomer shift, 0.023 mm/sec for quadrupole splitting, and l.44Vo on individual peak area data. Probable errors on different aliquots of the same sample are approximately +0.02 mm/sec for isomer shift and quadrupole splittings, and -rl.sVo on area data for well-resolved peaks.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Interlaboratory and intralaboratory variability in pulmonary function testing. A 13-year study using a normal biologic control.

The purpose of this study was to document the precision with which measurements can be made on a normal subject as a "biologic control" when comparisons are made both on an intralaboratory and interlaboratory basis. One individual had a total of about 300 routine pulmonary function measurements in 22 laboratories during a 13-year period. In this study, significant variation was found in interla...

متن کامل

Assessment of Reproducibility of Geometric Distortion in MRI using Phantom Measurements

Introduction:  Image  distortion  is  one  of  the  major  problems  of  magnetic  resonance  imaging  (MRI) for use in 3DMRI, velocity MRI, FMRI and radiotherapy treatment planning (RTTP). It is  widely known that the most obvious effect of the inhomogenity of the magnetic fields and the  nonlinearity  of  the  gradient  is  the  Geometric  Distortion  of  MR  tomograms.  In  this  study,  the...

متن کامل

Method validation by interlaboratory studies of improved hydrophilic oxygen radical absorbance capacity methods for the determination of antioxidant capacities of antioxidant solutions and food extracts.

Hydrophilic oxygen radical absorbance capacity (H-ORAC) is a method for evaluating antioxidant capacities of solutions of hydrophilic compounds. In this study, we improved the original method for H-ORAC determination, and evaluated the precision of the two improved methods (methods A and B) by interlaboratory studies using 5 antioxidant solutions and 5 food extracts as test samples. An interlab...

متن کامل

Possibility and Reproducibility of Renal Assessing and Size Measurement by Three- Dimensional vs Two- Dimensional Ultrasounographv in Dogs

Objective- To determine the possibility and reproducibility of three-dimensional ultrasonography (3DUS)and comparison of the achieved measurements to normal two-dimensional ultrasonography (2DCS)Design- Descriptive studyAnimals- 10 young mixed normal dogs, age 1.5-2.5 year, weighing 9.7-12 kg Procedure- Renal width, length, and depth measured in coron al and transverse sections. The measurement...

متن کامل

Comparison of Double and Single Leg Weight-Bearing Radiography in Determining Knee Alignment

  Background: Knee malalignment is an important modifiable cause of osteoarthritis (OA). Surgical therapeutic procedures depend on proper knee alignment assessment. The purpose of this study was to compare knee alignment parameters between double and single leg weight-bearing radiographs and to evaluate the reproducibility of inter- and intra-observer measurements. Methods: One hundred eight p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007