Development of Absorbable, Antibiotic-Eluting Sutures for Ophthalmic Surgery
نویسندگان
چکیده
PURPOSE To develop and evaluate an antibiotic-eluting suture for ophthalmic surgery. METHODS Wet electrospinning was used to manufacture sutures composed of poly(L-lactide), polyethylene glycol (PEG), and levofloxacin. Size, morphology, and mechanical strength were evaluated via scanning electron microscopy and tensile strength, respectively. In vitro drug release was quantified using high performance liquid chromatography. In vitro suture activity against Staphylococcus epidermidis was investigated through bacterial inhibition studies. Biocompatibility was determined via histological analysis of tissue sections surrounding sutures implanted into Sprague-Dawley rat corneas. RESULTS Sutures manufactured via wet electrospinning were 45.1 ± 7.7 μm in diameter and 0.099 ± 0.007 newtons (N) in breaking strength. The antibiotic release profile demonstrated a burst followed by sustained release for greater than 60 days. Increasing PEG in the polymer formulation, from 1% to 4% by weight, improved drug release without negatively affecting tensile strength. Sutures maintained a bacterial zone of inhibition for at least 1 week in vitro and elicited an in vivo tissue reaction comparable to a nylon suture. CONCLUSIONS There is a need for local, postoperative delivery of antibiotics following ophthalmic procedures. Wet electrospinning provides a suitable platform for the development of sutures that meet size requirements for ophthalmic surgery and are capable of sustained drug release; however, tensile strength must be improved prior to clinical use. TRANSLATIONAL RELEVANCE No antibiotic-eluting suture exists for ophthalmic surgery. A biocompatible, high strength suture capable of sustained antibiotic release could prevent ocular infection and preclude compliance issues with topical eye drops.
منابع مشابه
Component Rhinoplasty
BACKGROUND According to statistics of American Society of Plastic Surgeons, cosmetic rhinoplasty was the second most frequently performed cosmetic surgery. This study shares the experiences with component rhinoplasty. METHODS From 2004 to 2010, all patients underwent aesthetic nasal surgery were enrolled. The patients requiring only correction of septal deviation and those presenting with cl...
متن کاملA clinical survey
During the last decade ophthalmic surgeons have shown increasing interest in absorbable sutures, though a large body of opinion still favours silk and synthetic fibres. Hitherto, prejudice against catgut centred in the uncertainty of tissue reaction, wound healing, and absorption, and physical defects such as brittleness and unsuitable needles. The change of outlook follows improved manufacturi...
متن کاملComparative trial of Dexon (polyglycolic acid), collagen, and silk sutures in ophthalmic surgery.
The tissue reaction, absorption, and handling properties of Dexon synthetic absorbable sutures, which are made from polymerized hydroxyacetic acid, were compared with those of silk and collagen in 51 eye operations, consisting mainly of cataract extractions and squint corrections. There was no significant difference between the sutures as regards degree of tissue reaction. The Dexon sutures wer...
متن کاملAn improved surgical technique for pterygium excision with intraoperative application of mitomycin-C.
A surgical technique was designed to improve safety after pterygium excision with intraoperative application of mitomycin-C (MMC). A limbic incision was performed in 40 eyes. The body of the pterygium was dissected from the episclera to allow its excision. Care was taken to avoid excessive delamination and cauterization of tissues. A 0.02% MMC solution was then applied. Only at the end of the s...
متن کاملMechanical properties of suture materials in general and cutaneous surgery.
Comprehensive studies comparing tensile properties of sutures are over 25 years old and do not include recent advances in suture materials. Accordingly, the objective of this article is to investigate the tensile properties of commonly used sutures in cutaneous surgery. Thirteen 3-0 sized modern sutures (four nonabsorbable and nine absorbable) were tensile tested in both straight and knotted co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 6 شماره
صفحات -
تاریخ انتشار 2017