Contrast-modulation flicker: Dynamics and spatial resolution of the light adaptation process
نویسندگان
چکیده
We report a perceptual phenomenon that originates from a nonlinear operation during the visual process, and we use these observations to study the functional organization of the responsible nonlinearity; the regulation of visual sensitivity to light. When the contrast of a high frequency grating was modulated while its spatial and temporal average luminance was kept constant, observers saw brightness changes or desaturation in the field. If the contrast was modulated periodically between zero and a peak value, observers saw vivid flicker (contrast-modulation flicker), and this flicker could be seen even when the grating was too fine to be visually resolved as a pattern. This uniform-field flicker can be nulled by a modulation of space-average luminance at the contrast-modulation frequency, with appropriate phase and modulation depth. Contrast-modulation flicker is still measurable with gratings at 100 cycles/deg. The dynamics of contrast-modulation flicker suggest that it results from an early sensitivity-controlling mechanism, acting very rapidly (within about 20 msec). Its dependence on stimulus spatial frequency implies a strictly local luminance nonlinearity, one that either resides within individual photoreceptors or operates on signals from individual receptors.
منابع مشابه
Design and Fabrication Process of MTF Phantom CT Scan
Introduction: One of the main steps in the optimization process in diagnostic imaging is the quality control of radiology devices. The usual method of CT scan calibration is used of a phantom. The phantom created a certain weakening for the radiation through which it passes. One of the most suitable methods for quantitative analysis of the resolution and contrast in CT scan im...
متن کاملLocal nonlinearity in S-cones and their estimated light-collecting apertures
When an high frequency grating of high retinal contrast is presented intermittently by modulating its contrast at constant average luminance, observers experience uniform field flicker, even if the grating is too fine to be resolved. For long and middle wavelength cones, this contrast-modulation flicker can be seen for fringe periods as small as the diameter of a cone [MacLeod & He (1993). Natu...
متن کاملA quality assurance program for an amorphous silicon electronic portal imaging device using in-house developed phantoms: a method development for dosimetry purposes
Background: Electronic portal imaging devices (EPIDs) play an important role in radiation therapy portal imaging, geometric and dosimetric verifications. A successful utilization of EPIDs for imaging and dosimetric purposes requires a reliable quality control process routine to be carried out regularly. In this study, two in-house phantoms were developed and analyzed for implementation in a qua...
متن کاملInvestigation of the Spatial Resolution of MR-Based Polymer Gel Dosimetry versus Film Densitometry using Dose Modulation Transfer Function
Introduction: The conventional methods of dosimetry are not capable of dosimetry in such a small volume of less than one cubic millimeter. Although the polymer gel dosimetry method based on magnetic resonance imaging (MRI) could achieve three dimensional dosimetry with high resolution, a spatial resolution evaluation based on gel dose modulation transfer function has not been investigated yet. ...
متن کاملInvestigation of the effect of source distance and scattering medium on spatial resolution and contrast of Gamma camera images [Persian]
By identifying the effect of any parameter such as distance, attenuation and scattering on the Line Spread Function (LSF), one can compensate the quantitative and qualitative destructive effect of such parameters by deconvolution method. Using a 99mTC line source, this study was performed on a single head ADAC SPECT system operating in planar mode. Variation of FWTM and FWHM and LSFs as a...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Vision Research
دوره 38 شماره
صفحات -
تاریخ انتشار 1998