4D Processing of Gated SPECT Images Using Deformable Mesh Modeling

نویسندگان

  • Jovan G. Brankov
  • Yongyi Yang
  • Miles N. Wernick
چکیده

In this work we present a new 4D approach for reducing noise in gated SPECT perfusion images while preserving accurate cardiac motion. The method is based on motioncompensated temporal smoothing using a deformable content-adaptive mesh to model cardiac motion. We use a new, fast method for initial mesh generation. This mesh is then deformed to track cardiac motion and smoothing is performed along motion tractories through the space-time coordinate system.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Spatiotemporal processing of gated cardiac SPECT images using deformable mesh modeling.

In this paper we present a spatiotemporal processing approach, based on deformable mesh modeling, for noise reduction in gated cardiac single-photon emission computed tomography images. Because of the partial volume effect (PVE), clinical cardiac-gated perfusion images exhibit a phenomenon known as brightening-the myocardium appears to become brighter as the heart wall thickens. Although bright...

متن کامل

Motion-compensated post-processing of gated cardiac SPECT images using a deformable mesh model

We present a post-reconstruction motion-compensated spatio-temporal filtering method for noise reduction in cardiac gated SPECT images. SPECT imaging suffers from low photon count due to radioactive dose limitations resulting in a high noise level in the reconstructed images. This is especially true in gated cardiac SPECT where the total number of counts is divided into a number of gates (time ...

متن کامل

Motion-Compensated 4D Processing of Gated SPECT Perfusion Studies

† Research supported by NIH/NHLBI Grant HL65425. Abstract—In this paper we present two 4D motion-compensated reconstruction algorithms for gated cardiac SPECT. The algorithms are based on a deformable content-adaptive mesh model, a compact image representation that is well suited for motion tracking of non-rigid objects like the heart. In this paper we introduce a reconstruction method using in...

متن کامل

Deformable biomechanical models: Application to 4D cardiac image analysis

This article describes a methodology for creating a generic volumetric biomechanical model from different image modalities and segmenting time series of medical images using this model. The construction of such a generic model consists of three stages: geometric meshing, non-rigid deformation of the mesh in images of various modalities, and image-to-mesh information mapping through rasterizatio...

متن کامل

4D deformable models with temporal constraints: application to 4D cardiac image segmentation

Segmentation of time series of 3D cardiac images is clinically used for the assessment of the mechanical function of the left ventricle. To take into account the 4D (3D+T) nature of those images, we propose to extend the deformable surface framework by introducing time-dependent constraints. Thus, in addition to computing an internal force for enforcing the regularity of the deformable model, p...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2001