Developing a New Dental Implant Design and Comparing its Biomechanical Features with Four Designs
نویسندگان
چکیده
BACKGROUND As various implant geometries present different biomechanical behaviors, the purpose of this work was to study stress distribution around tapered and cylindrical threaded implant geometries using three-dimensional finite element stress analysis. METHODS Seven implant models were constructed using Computer Assisted Designing system. After digitized models of mandibular section, the crowns were created. They were combined with implant models, which were previously imported into CATIA software. The combined solid model was transferred to ABAQOUS to create a finite element meshed model which was later analyzed regarding the highest maximum and minimum principal stresses of bone. RESULTS For all models, the highest stresses of cortical bone were located at the crestal cortical bone around the implant. Threaded implants, triangular thread form and taper body form showed a higher peak of tensile and compressive stress than non-threaded implants, square thread form and straight body form, respectively. A taper implant with triangular threads, which is doubled in the cervical portion of the body, had a significantly lower peak of tensile and compressive stress in the cortical bone than straight/taper triangular or square threaded implant forms. CONCLUSION For the investigation of bone implant interfacial stress, the non-bonded state should be studied too. Confirmative clinical and biological studies are required in order to benefit from the results of this study.
منابع مشابه
Comparison of the Effect of Ball and Bar Attachment Designs on Retention and Stability of Mandibular Implant-Supported Overdentures
Objectives: The present study evaluated the effect of bar and ball attachment designs on retention and stability of a mandibular overdenture supported by four implants. Methods: An edentulous mandibular acrylic resin model with four implants in the anterior part of the ridge (A, B, D and E) was fabricated. A metal framework simulating the overdenture was also fabricated. Totally, 30...
متن کاملFinite Element Analysis of Different Hip Implant Designs along with Femur under Static Loading Conditions
Background: The hip joint is the largest joint after the knee, which gives stability to the whole human structure. The hip joint consists of a femoral head which articulates with the acetabulum. Due to age and wear between the joints, these joints need to be replaced with implants which can function just as a natural joint. Since the early 19th century, the hip joint arthroplasty has evolved, a...
متن کاملImplant crest module: a review of biomechanical considerations.
The success of dental implants has long been established through various studies with a particular emphasis laid on an implant design. Crest module is that portion of a two-piece metal dental implant, designed to hold the prosthetic components in place and to create a transition zone to the load bearing implant body. Its design, position in relation to the alveolar crest, and an abutment implan...
متن کاملEvaluation of Strain Distribution in Bone around Implant in Treatment Design of Overdentures Using Computer and Modeling of Finite Elements
Introduction: Introduction: Few studies have investigated the distribution of stress around implants. In this study the distribution of stress in bones around implants was investigated in five overdenture (OD) treatment designs including OD-1, OD-2, OD-3, OD-4 and OD-5. Materials and methods: The Catia modeling software was used in order to simulate the tooth/implant model and bone. First, the ...
متن کاملThe Effect of Different Marginal Designs on the Fracture Resistance of Monolithic Zirconia Crowns
Abstract Background and Aim: One of the major problems of all ceramic restorations is their probable fracture against the occlusal force. The aim of the present in vitro study is to compare the effect of three marginal designs (shoulder, sloped shoulder, chamfer) on the fracture resistance of monolithic zirconia crowns. Materials and methods: In this in vitro study, three PEEK dies with cham...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 7 شماره
صفحات -
تاریخ انتشار 2010