Nuclear Imaging Incremental Value of Combined Perfusion and Function Over Perfusion Alone by Gated SPECT Myocardial Perfusion Imaging for Detection of Severe Three-Vessel Coronary Artery Disease
نویسنده
چکیده
OBJECTIVES We hypothesized that combining functional assessment to perfusion enhances the ability of electrocardiographic gating Tc-99m sestamibi single photon emission computed tomography (gated SPECT) myocardial perfusion imaging (MPI) to detect defects in multiple vascular territories in patients with severe three-vessel coronary artery disease (3VD). BACKGROUND In patients with 3VD, perfusion defects in multiple vascular territories may not always be evident due to globally reduced perfusion. METHODS Gated SPECT MPIs were interpreted sequentially with perfusion first, followed by combined perfusion/function, in 143 patients with angiographic 3VD and a control group of 112 non-3VD patients. All patients underwent coronary arteriography within one month of MPI. RESULTS In 3VD patients, combined perfusion/function analysis yielded significantly greater numbers of abnormal segments/patient (6.2 4.7 vs. 4.1 2.8, p 0.001) and more defects in multiple vascular territories (60% vs. 46%, p 0.05) than perfusion alone. In the control group, there were no differences between the combined perfusion/function and perfusion alone interpretations. Multivariate analysis of 15 different clinical, stress, and scintigraphic variables in all patients revealed age (p 0.0001) and number of abnormal vascular territories by combined perfusion/function (p 0.0001) to be the most powerful predictors of 3VD. Addition of functional data to clinical, stress, and perfusion yielded a significant increase in the predictive value of 3VD (global chi-square: 131.7 vs. 89.8, p 0.00001). Specificity of combined perfusion/function analysis was not lower than perfusion alone (72% vs. 69%, p NS). CONCLUSIONS Adjunctive assessment of function with perfusion by gated SPECT MPI enhances the detection of defects in multiple vascular territories in patients with severe 3VD, without adversely affecting its specificity. (J Am Coll Cardiol 2003;42:64–70) © 2003 by the American College of Cardiology Foundation
منابع مشابه
Diagnostic Accuracy of Gated-SPECT Myocardial Perfusion Imaging and Exercise Stress Test for Diagnosis of Coronary Artery Disease
Background and Objective:Accurate diagnosis of CAD using noninvasive procedures is of great importance. The aim of the study is to assess diagnostic accuracy of myocardial perfusion imaging and compare it with exercise stress test in order to decipher a more accurate and cost-effective method for CAD detection. Materials and Methods:Of 430 consecutive patients suspected with CAD, 104 performed...
متن کاملThe myocardial perfusion scintigraphy in asymptomatic diabetic patients
Introduction: Asymptomatic diabetic patients are at increased risk of cardiovascular complications. Myocardial perfusion scan may be effective in risk evaluation in this population. Methods: 106 asymptomatic diabetic patients (age: min: 37, max: 82, mean: 57.73±8.88), including 56 females (52.8%) and 50 males (47.2%) were enrolled in the study. Myocardial perfusion scintigraphy was performed b...
متن کاملPerformance of myocardial perfusion imaging using multi-focus fan beam collimator with resolution recovery reconstruction in a comparison with conventional SPECT
Objective: IQSPECT is an advanced high-speed SPECT modality for performing myocardial perfusion imaging (MPI), which uses a multi-focus fan beam collimator with resolution recovery reconstruction. The aim of this study was to compare IQSPECT compared with conventional SPECT interms of performance based on standard clinical protocols. In addition, we examined the concordance between convention...
متن کاملSuppurative bacterial myocarditis: echocardiographic and pathological findings.
min International Trial Study Group. Circulation 1995;91:313–319. 32. Smanio P, Watson D, Segalla D, Vinson E, Smith W, Beller G. Value of gating of Technetium-99m sestamibi single-photon emission computed tomographic imaging. J Am Coll Cardiol 1997;30:1687–1692. 33. Lima RS, Watson DD, Goode AR, Siadaty MS, Ragosta M, Beller GA, Samady H. Incremental value of combined perfusion and function ov...
متن کاملComparison of the myocardial perfusion and wall motion results by ECG-Gated 99mTc-MIBI SPECT, before and after CABG for evaluation of myocardial viability [Persian]
It is of value to determine the amount of viable myocardial tissue in patients suffering from chronic coronary artery disease and ventricular dysfunction. Having the capability of evaluating both myocardial perfusion and function, simultaneously, myocardial scanning by ECG-Gated is an appropriate method for this purpose. The aim of this study was to compare the results of myocardial perfu...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2016