Meeting the criteria: linking biofilter design to fecal indicator bacteria removal

نویسنده

  • Megan A. Rippy
چکیده

The capture, treatment, and reuse of storm-water runoff are win–win propositions that can lead to improvements in both human water security and ecosystem health. Although not all treatment technologies facilitate the capture, treatment, and reuse of water, biofilters do. Biofilters are engineered analogues of natural systems that use low energy, natural processes to treat stormwater. Biofilter design is closely linked to treatment efficiency. As such, specific design components, such as submerged zones (SZs: saturated, organic-rich layers near the base of biofilters), can significantly affect contaminant removal. Of particular interest, is the utility of SZ biofilter designs for removing indicators of pathogens, the so-called fecal indicator bacteria (FIB). FIB exist at high concentrations in stormwater, sometimes several orders of magnitude above recreational, nonpotable reuse, or drinking water standards, and have been identified as one of the primary barriers to stormwater reuse. A comparison of FIB removal values from literature indicates that SZ systems significantly enhance FIB removal (∼10-fold) relative to other design configurations (p< 0.05). Processes that may contribute to this effect include physicochemical filtration, biofilm formation, and protistan grazing, amongst others. A high degree of synergy exists between processes, and many unknowns remain. Model frameworks developed for evaluation of similarly synergistic systems, including biofilter analogues like the vadose zone, may be useful for addressing these unknowns and informing future biofilter design. © 2015 Wiley Periodicals, Inc.

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fungi Occurrence Assessment in Drinking Water Distribution Systems and Its Relationship with Fecal Indicator Bacteria

Introduction: As recommended by World Health Organization, consumption of the fungal contaminated water does not cause to serious infection, but may lead to healthy or aesthetic problems. The aim of this research was to assess the occurrence of fungi in water and its relationship with fecal indicator bacteria. Materials and Methods: 110 water samples were collected from different location of w...

متن کامل

Evaluation of pathogenic indicator bacteria in structural best management practices.

This study evaluated the bacteria removal efficiency, re-suspension and survivability within two structural Best Management Practices (BMPs) called Vortechs installed at two different sites in Providence, Rhode Island. Twelve rain storms were sampled during years 2004 and 2005. Five pathogenic indicator bacteria, E. coli, enterococci, fecal streptococci, total coliform, fecal coliform, were ana...

متن کامل

The Performance of Compost Biofilter for Hydrogen Sulfide Removal from Contaminated Air

In order to evaluate the performance of biofilter for H2S removal from contaminated air, a 120×14 cm column biofilter was constructed using clear polyacrylic material in conjunction with H2S production and control systems. The column was divided into four stages using perforated plates. The column was packed with a mixture of mushroom compost and snail shell (4:1).&#10 The performance of biofil...

متن کامل

Stormwater Biofilters as Barriers against Campylobacter jejuni, Cryptosporidium Oocysts and Adenoviruses; Results from a Laboratory Trial

Biofilters are a widely used stormwater treatment technology. However; other than some evidence regarding non-pathogenic indicator microorganisms; there are significant knowledge gaps in the capacity of stormwater biofilters to remove actual pathogens and how this removal is impacted by biofilter design elements and operational conditions. In this study; we explored the capacity of stormwater b...

متن کامل

The Performance of Compost Biofilter for Hydrogen Sulfide Removal from Contaminated Air

In order to evaluate the performance of biofilter for H2S removal from contaminated air, a 120×14 cm column biofilter was constructed using clear polyacrylic material in conjunction with H2S production and control systems. The column was divided into four stages using perforated plates. The column was packed with a mixture of mushroom compost and snail shell (4:1). The performance of biofilte...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

برای دانلود متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2015