Fast and Noninvasive Characterization of Suspicious Lesions Detected at Breast Cancer X-Ray Screening: Capability of Diffusion-weighted MR Imaging with MIPs.
نویسندگان
چکیده
PURPOSE To evaluate the ability of a diagnostic abbreviated magnetic resonance (MR) imaging protocol consisting of maximum intensity projections (MIPs) from diffusion-weighted imaging with background suppression (DWIBS) and unenhanced morphologic sequences to help predict the likelihood of malignancy on suspicious screening x-ray mammograms, as compared with an abbreviated contrast material-enhanced MR imaging protocol and a full diagnostic breast MR imaging protocol. MATERIALS AND METHODS This prospective institutional review board-approved study included 50 women (mean age, 57.1 years; range, 50-69 years), who gave informed consent and who had suspicious screening mammograms and an indication for biopsy, from September 2014 to January 2015. Before biopsy, full diagnostic contrast-enhanced MR imaging was performed that included DWIBS (b = 1500 sec/mm(2)). Two abbreviated protocols (APs) based on MIPs were evaluated regarding the potential to exclude malignancy: DWIBS (AP1) and subtraction images from the first postcontrast and the unenhanced series (AP2). Diagnostic indexes of both methods were examined by using the McNemar test and were compared with those of the full diagnostic protocol and histopathologic findings. RESULTS Twenty-four of 50 participants had a breast carcinoma. With AP1 (DWIBS), the sensitivity was 0.92 (95% confidence interval [CI]: 0.73, 0.98), the specificity was 0.94 (95% CI: 0.77, 0.99), the negative predictive value (NPV) was 0.92 (95% CI: 0.75, 0.99), and the positive predictive value (PPV) was 0.93 (95% CI: 0.75, 0.99). The mean reading time was 29.7 seconds (range, 4.9-110.0 seconds) and was less than 3 seconds (range, 1.2-7.6 seconds) in the absence of suspicious findings on the DWIBS MIPs. With the AP2 protocol, the sensitivity was 0.85 (95% CI: 0.78, 0.95), the specificity was 0.90 (95% CI: 0.72, 0.97), the NPV was 0.87 (95% CI: 0.69, 0.95), the PPV was 0.89 (95% CI: 0.69, 0.97), and the mean reading time was 29.6 seconds (range, 6.0-100.0 seconds). CONCLUSION Unenhanced diagnostic MR imaging (DWIBS mammography), with an NPV of 0.92 and an acquisition time of less than 7 minutes, could help exclude malignancy in women with suspicious x-ray screening mammograms. The method has the potential to reduce unnecessary invasive procedures and emotional distress for breast cancer screening participants if it is used as a complement after the regular screening clarification procedure.
منابع مشابه
بررسی ارزش تشخیصی اسکن 99mTc-MIBI (Scintimammography) در بدخیمی های پستان
The breast cancer is common in females.Early detection with safe , convenient , noninvasive and accessible diagnostic tools are important. X- ray mammography is still the first choice imaging for breast cancer, but has low specificity and limited value in dense breast and surgically scarred breasts. In recent years , MIBI scintimammography has been used for this purpose. The...
متن کاملComparison between MRS and DWI in MRI of breast cancer
Introduction: Breast cancer is the most common cancer in women and is the second leading cause of cancer death (after lung cancer) in people throughout the world. Today, MRI is being used because of the limitations of x-ray mammography to detect breast cancer. Non-contrast sequences were associated to CE sequences in a breast MRI protocol for the sake of appraising morphologic ...
متن کاملSignal Intensity of High B-value Diffusion-weighted Imaging for the Detection of Prostate Cancer
Background: Diffusion-weighted imaging (DWI) is a main component of multiparametric MRI for prostate cancer detection. Recently, high b value DWI has gained more attention because of its capability for tumor characterization. Objective: To assess based on histopathological findings of transrectal ultrasound (TRUS)-guided prostate biopsy as a reference, an...
متن کاملبررسی ارزش Diffusion Weighted Imaging در تصاویر MRI برای تشخیص سرطان پروستات
Background: Prostate cancer is the third leading cause of death and is the most common cause of cancer in elderly men. Regarding to the low accuracy of screening methods such as prostate-specific antigen (PSA), Digital Rectal Examination (DRE) and trans rectal ultrasound (TRUS) in detection and localization of tumor, Magnetic Resonance Imaging (MRI) and Diffusion Weighted Imaging (DWI) attracte...
متن کاملOn a fractional order calculus model in diffusion weighted breast imaging to differentiate between malignant and benign breast lesions detected on X-ray screening mammography
OBJECTIVE To evaluate a fractional order calculus (FROC) model in diffusion weighted imaging to differentiate between malignant and benign breast lesions in breast cancer screening work-up using recently introduced parameters (βFROC, DFROC and μFROC). MATERIALS AND METHODS This retrospective analysis within a prospective IRB-approved study included 51 participants (mean 58.4 years) after writ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Radiology
دوره 278 3 شماره
صفحات -
تاریخ انتشار 2016