Long-term follow up of secundum atrial septal defect closure with the amplatzer septal occluder.
نویسندگان
چکیده
BACKGROUND During the past 15 years, closure of a secundum atrial septal defect (ASD) has moved from a surgical to a percutaneous transcatheter approach. Few long-term studies of the efficacy and safety of closure of an ASD by an Amplatzer septal occluder (ASO) exist. METHODS To examine the long-term results of secundum ASD closure using the ASO, data on 94 patients who underwent secundum ASD closure with the ASO between 1998 and 2002 were available and reviewed. Data regarding residual shunt, chest pain, palpitations, arrhythmias, headaches, transient ischemic attacks, cerebrovascular accidents, and mortality were collected. RESULTS Seven (7.4%) subjects had residual shunts immediately following ASO placement. During follow-up, 4 residual shunts closed for a complete closure rate of 97%. Eighteen (19%) patients reported chest pain during the follow-up period. Twenty-three patients (24%) reported palpitations during the follow up period, 7 were documented arrhythmias, including supraventricular tachycardia, atrial fibrillation, and premature ventricular beats. Migraine headaches were new-onset in 4 patients. Migraine cessation occurred in 2 patients after secundum ASD closure. One child died from a cerebral vascular event 18 months following device placement. Only 1 patient developed mild aortic insufficiency. CONCLUSION These data indicate that for up to 120 months of patient follow-up, the ASO continues to be a safe device. Residual shunts and arrhythmias have low incidence post-ASO placement. Given the mortality in one high-risk patient, further investigation into anti-platelet therapy after device placement is warranted.
منابع مشابه
Long-term outcome of transcatheter secundum-type atrial septal defect closure using Amplatzer septal occluders.
OBJECTIVES The aim of this study was to assess long-term results of percutaneous closure of secundum-type atrial septal defect (ASD II) using Amplatzer septal occluders (ASO). BACKGROUND Only immediate-, short-, and intermediate-term results of ASO implantation are known so far. METHODS Between September 1995 and January 2000, 151 patients underwent a successful percutaneous closure of ASD ...
متن کاملCongenital Heart Disease Transcatheter Closure of Atrial Septal Defects with the Amplatzer Septal Occluder Clinical Results
Objective: To assess the short-term outcome following transcatheter closure of secundum atrial septal defect (ASD) in our hospital. Patients and Methods: Between June 2000 and November 2001, 20 patients diagnosed as secundum atrial septal defects underwent transcatheter closure of their defects using the Amplatzer septal occluder (ASO) device. Indications for 18 patients were larger atrial sept...
متن کاملIntermediate and long-term outcome of patients after device closure of ASD with special reference to complications.
BACKGROUND Device closure of Secundum atrial septal defect (ASD) is an accepted mode of treatment in selected patients with a suitable defect. The major initial concern over the long-term outcome has been erosions and more recently development of aortic regurgitation. Objective was to assess the intermediate and long term outcome of patients with device closure of ASD with special reference to ...
متن کاملClosure of Secundum Atrial Septal Defects With the AMPLATZER Septal Occluder
BACKGROUND Prospective data on the medium-term safety and effectiveness of the AMPLATZER Septal Occluder in clinical practice are not available. The objective of this study was to prospectively evaluate the risk of hemodynamic compromise and obtain medium-term survival data on patients implanted with the AMPLATZER Septal Occluder for percutaneous closure of secundum atrial septal defects. MET...
متن کاملLive/Real Time Three-Dimensional Trans Esophageal Echocardiographic Findings in Amplatzer ASD Closure Devices in Adults
Six female patients aged from 19 to 73 years, with ostium secundum atrial septal defect underwent closure procedure with Amplatzer septal occluder device. Three-dimensional Echocardiography (3D-TEE) was done during the procedure or one day after the procedure. 3D-TEE provides incremental value over Two- dimensional trans-esophageal echocardiography in measuring Amplatzer septal occluder disc si...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Congenital heart disease
دوره 5 1 شماره
صفحات -
تاریخ انتشار 2010