A combined video and gamma ray imaging system for robots in nuclear environments

نویسنده

  • M. Squillante
چکیده

An integrated imaging sensor system is being developed to enhance operations of robots and telerobotic systems used in nuclear industry . This system combines a gamma ray image of the distribution of radioactivity with a video image of the area, allowing a rapid and intuitive determination of the source location . The gamma ray imaging system is based upon a position sensitive photomultiplier tube, a segmented scintillator, and a pinhole collimator which provides high quality images in the energy range of 0.1 to 1.5 MeV. The design and measured performance of a prototype of this system will be discussed. Robots are becoming increasingly important throughout the nuclear industry [1] . They are commonly used to improve operations and maintenance, lower operating costs, and reduce exposure to workers [2] . However, the capabilities of existing robots are limited by the systems used to sense their surroundings, which often include visual imaging systems and nuclear survey instruments. These survey instruments are useful for making rapid, discrete point measurements of radiation intensity but do not give directional information regarding the radiation [3] . This makes locating a source cumbersome and time-consuming and does not allow the robot or operator to easily visualize the distribution of radioactivity in the local environment . We are developing an instrument which will overcome these difficulties by combining a video camera with a portable gamma ray imaging system to produce an image of the radioactivity, superimposed on a video image of the same field of view, allowing an operator to rapidly and remotely locate radioactive sources . We have developed a prototype of such an instrument which has been used to image isotopic sources with energies between 0.1 and 1.5 MeV. We have also developed a Monte Carlo model to simulate the performance of this instrument in the presence of the radiation fields found in the nuclear industry [4]. We anticipate achieving an angular resolution for the nuclear image of 6°, or 1 m spatial resolution at 10 m, with an 0168-9002/94/$07.00 © 1994 Elsevier Science B.V. All rights reserved SSDI0168-9002(94)00765-9 efficiency of 3 X 10 -b at 1 m, which is suitable for many nuclear applications . 2. Prototype design NUCLEAR INSTRUMENTS &METHODS IN PHYSICS RESEARCH Section A The prototype imager combines a gamma ray imaging system with a conventional video camera and personal computer-based data acquisition and display system . A block diagram of the prototype is shown in Fig. 1 . The gamma ray imager is based upon a position sensitive photomultiplier tube (PSPMT) coupled to a scintillator and collimator . A PSPMT is a unique photomultiplier tube which combines the sensitivity and energy resolution of conventional PMTS with the ability to obtain two-dimensional position information [5]. Most importantly, because the PSPMT is only 3 in . in diameter, the gamma ray imager is sufficiently small and light to be used with many existing robots . The characteristics of PSPMTs have been discussed by many authors [6,7] . The PSPMT is a single photon imaging device, with each incident light pulse producing four analog output pulses from which the position and energy of the incident gamma ray can be computed. The energy resolution is comparable to that obtained by a conventional PMT although the gain varies significantly with position . The spatial resolution is inversely proportional to the square root of the number of optical photons per unit area incident on the photocathode . In order to obtain positional information a collimator must be used to restrict the solid angle which may illuminate an image pixel. In the prototype instrument use a 3 R. Redus et al. /Nucl. Instr. andMeth. in Phys. Res. A353 (1994) 324-327 Fig. 1 . Block diagram of prototype video/gamma ray imaging system . cm thick lead pinhole collimator with a conical hole, with the base facing towards the scintillator (see Fig. 1). The cone allows imaging throughout the field of view with no attenuation. A pinhole collimator has several advantages over other types, including ease of fabrication, ease of operation, and angular resolution independent of distance which permits straightforward comparison with the video image. The main factor determining the efficiency and spatial resolution of the system is the angle subtended by the collimator pinhole. The distance from the front of the collimator to the PSPMT determines the angular field of view, while the diameter of the pinhole determines the angular resolution and geometric efficiency . At higher energies, the effective pinhole diameter is increased due to penetration near the edges of the pinhole. Diverging hole collimators can also be used for imaging high energy sources when designed to provide constant angular resolution . Such a collimator should be designed with the fields of view of individual holes overlapping only at infinity [8,9]. In the limit where the distance between the source and collimator are large relative to collimator thickness, diverging hole and pinhole collimators, with the same hole size and the same distance between the scintillator and collimator face, have the same angular resolution and geometric efficiency. The multiple hole collimator does have some potential advantages . High energy gamma rays will penetrate the edges of the conical pinhole, causing penumbral penetration, which results in reduced resolution . This effect is larger than septal penetration in the cylindrical holes of a multiple hole collimator at the same energy . In addition, in the pinhole radiation can scatter from the aperture throughout the image plane, while scattering from the multiple hole collimator only affects a single hole . The multiple hole collimator is however much harder to fabricate, and as shown below, a pinhole collimator provides sufficient image quality for most applications of interest. Other collimator geometries are possible . For example, a coded aperture collimator can be used with the PSPMT and would lead to increased geometric efficiency but this does not automatically improve the signal-to-noise ratio. For point sources in the absence of background radiation, coded aperture methods reduce the noise in pixels with a strong signal . However, for broadly distributed source distributions and point sources in the presence of significant background radiation, coded aperture collimators result in higher statistical noise everywhere compared with conventional imaging [10]. A coded aperture collimator is generally not advantageous in the radiation fields experienced by robots in nuclear operations . A scintillator is used to convert the energy of the incident gamma rays into optical photons which can be detected by the PSPMT. In order to provide good stopping power for gamma rays with energy above 1 MeV it is necessary to use a thick scintillator . The resolution of the X-ray interaction at the PSPMT photocathode is significantly degraded with a thick conventional scintillator because of light spreading in the scintillator. For this reason, a segmented scintillator was used . The scintillator was made of BGO, 1 cm thick, with segments 2.5 mm on centers, separated by (MgO) optical reflector material . The scintillator was fabricated by ScinTech, Inc. Photons generated within a given segment are always distributed uniformly over a 6.25 mm2 area of the photocathode . For energies between 0.1 and 1 MeV the measured PSPMT spatial resolution varies between 1 and 2.5 mm . The segment size, which determines the maximumpixel size, is half the dimension of the pinhole, to obtain good statistics and good resolution for photon energies > 0.1 MeV. 3. Experimental results 325 In the present laboratory prototype system the PSPMT is interfaced to a personal computer using a commercially available PSPMT Interface System [111 . This system acquires digitized coordinate and energy values, implements a position dependent energy discrimination and a uniformity correction to compensate for the non-uniformity of the PSPMT [12], and places the nuclear image into a buffer in the computer . The video image is acquired using a conventional video camera and an IDEC-8 video digitizer card . The video image is displayed in gray scale on the monitor, while the nuclear image is superimposed on the video image in real-time. The nuclear image is displayed in color to make it easier to locate the source . Fig. 2 shows images of several isotopic sources, located at 1 m distances, which were obtained with the prototype instrument . All three images were obtained with the same collimator and scintillator, with only the energy discrimination changed between images . Fig. 2a shows 80 1r,Ci of 60 with energy emissions at 117 and 132 MeV im Co, . .,aged at 1 m in 20 min. Fig. 2b shows 1 MCi of r37Cs, with energy emission at 662 keV, imaged at 1 m in 30 s. Fig. 2c shows 8.5 rnCi of Co, with energy emission at 122 keV, imaged at 1 m in 5 s. The gamma images were processed by contrast expansion and thresholding . This clearly demonstrates the ability of the system to image a wide

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Determination of virtual point for HPGe detector at various gamma rays energies by simulation and experimental methods

High Purity Germanium detectors (HPGe) are subdivisions of semiconductor detectors which are widely used in nuclear technology from space industry to nuclear medicine, due to their high resolution, low dead time, unlimited size and compatibility with a variety of environments. The( absolute and intrinsic) efficiency of the HPGe detector, which depends on the geometry of the source-detector syst...

متن کامل

Transition from analogue-to-digital nuclear electronics for precise gamma radiation spectroscopy: advantages and limitations

In this paper, digital signal processing for precise gamma ray spectroscopy is presented. The basis of this system is a 14bit waveform digitizer which samples the output of pre-amplifier signals directly. The advantages and limitations of the digital spectrometer compared with analog spectrometer has been tested and analyzed from precise gamma ray spectroscopy point of view. The results shows t...

متن کامل

An alternative mathematical modeling of the scintillation camera and framework for performance analysis of gamma-ray positioning algorithms

Introduction: Substantive amount of work has been done in modeling and analyzing the scintillation camera system processes including positioning and image formation. The goal of this work is to develop a framework for analyzing performance of nonlinear positioning methods upon construction of a mathematical model of the system. In this study, the photodetector array counts are ...

متن کامل

Design of Small Animal Computed Tomography Imaging for in vitro and in vivo Studies

Introduction: Mini Computed Tomography (mini-CT) was suggested in biomedical research to investigate tissues and small animals. We present designed and built a mini x-ray computed tomography (mini-CT) for small animals as well as industrial component imaging. Materials and Methods: The system used in this study includes a X-ray tube 20kV to 160kV and a flat pa...

متن کامل

Enhancing and verification of dose in external radiation therapy using Gd nanoparticles as a theranostic agent: A Monte Carlo simulation study

Introduction: Theranostics, in particular, the use of radionuclides with the capability of simultaneous imaging and treatment has opened new horizons in personalized treatment planning of targeted radiation therapy. In this approach, positive beta or gamma emitters are required for imaging and alpha, beta and Auger electrons for treatment purpose. On the other hand, studies hav...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2002