Comparison of bolus and infusion methods for receptor quantitation: application to [18F]cyclofoxy and positron emission tomography.

نویسندگان

  • R E Carson
  • M A Channing
  • R G Blasberg
  • B B Dunn
  • R M Cohen
  • K C Rice
  • P Herscovitch
چکیده

Positron emission tomography studies with the opiate antagonist [18F]cyclofoxy ([18F]CF) were performed in baboons. Bolus injection studies demonstrated initial uptake dependent on blood flow. The late uptake showed highest binding in caudate nuclei, amygdala, thalamus, and brainstem and the least accumulation in cerebellum. By 60 min postinjection, regional brain radioactivity cleared at the same rate as metabolite-corrected plasma, i.e., transient equilibrium was achieved. Compartmental modeling methods were applied to time-activity curves from brain and metabolite-corrected plasma. Individual rate constants were estimated with poor precision. The model estimate of the total volume of distribution (VT), representing the ratio of tissue radioactivity to metabolite-corrected plasma at equilibrium, was reliably determined. The apparent volume of distribution (Va), the concentration ratio of tissue to metabolite-corrected plasma during transient equilibrium, was compared with the fitted VT values to determine if single-scan methods could provide accurate receptor measurements. Va significantly overestimated VT and produced artificially high image contrast. These differences were predicted by compartment model theory and were caused by a plasma clearance rate that was close to the slowest tissue clearance rate. To develop a simple method to measure VT, an infusion protocol consisting of bolus plus continuous infusion (B/I) of CF was designed and applied in a separate set of studies. The Va values from the B/I studies agreed with the VT values from both B/I and bolus studies. This infusion approach can produce accurate receptor measurements and has the potential to shorten scan time and simplify the acquisition and processing of scan and blood data.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Calculation of Positron Distribution in the Presence of a Uniform Magnetic Field for the Improvement of Positron Emission Tomography (PET) Imaging Using GEANT4 Toolkit

Introduction Range and diffusion of positron-emitting radiopharmaceuticals are important parameters for image resolution in positron emission tomography (PET). In this study, GEANT4 toolkit was applied to study positron diffusion in soft tissues with and without a magnetic field for six commonly used isotopes in PET imaging including 11C, 13N, 15O, 18F, 68Ga, and 82Rb. Materials and Methods GEA...

متن کامل

Comparison of Bolus and Infusion Methods for Receptor ~uantitation: Application to [18~]~yclofoxy and Positron Emission Tomography

Positron emission tomography studies with the opiate antagonist ['8F]cyclofoxy (["FICF) were performed in baboons. Bolus injection studies demonstrated initial uptake dependent on blood flow. The late uptake showed highest binding in caudate nuclei, amygdala, thalamus, and brainstem and the least accumulation in cerebellum. By 60 min postinjection, regional brain radioactivity cleared at the sa...

متن کامل

Diagnostic Performance and Safety of Positron Emission Tomography Using 18F-Fluciclovine in Patients with Clinically Suspected High- or Low-grade Gliomas: A Multicenter Phase IIb Trial

Objective(s): The study objective was to assess the diagnostic performance of positron emission tomography (PET) for gliomas using the novel tracer 18F-fluciclovine (anti-[18F]FACBC) and to evaluate the safety of this tracer in patients with clinically suspected gliomas.Methods: Anti-[18F]FACBC was administered to 40 patients with clinically suspected high- or low-grade gliomas, followed by PET...

متن کامل

Background-Based Delineation of Internal Tumor Volumes on Static Positron Emission Tomography in a Phantom Study

Objective(s): Considering the fact that the standardized uptake value (SUV) of a normal lung tissue is expressed as x±SD, x+3×SD could be considered as the threshold value to outline the internal tumor volume (ITV) of a lung neoplasm. Methods: Three hollow models were filled with 55.0 kBq/mL fluorine18- fluorodeoxyglucose (18F-FDG) to represent tumors. The models were fixed to a barrel filled w...

متن کامل

Diagnostic Accuracy of Positron Emission Mammography with 18F-fluorodeoxyglucose in Breast Cancer Tumor of Less than 20 mm in Size

Objective(s): To investigate the diagnostic accuracy of positron emission mammography (PEM) and positron emission tomography/computed tomography (PET/CT) for small breast tumors of less than 20 mm in size.Methods: The study was conducted on a total of 100 subjects (i.e., 50 patients with pathologically proven breast cancer and 50 normal cases of medical screening). The total number of tumors wa...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Journal of cerebral blood flow and metabolism : official journal of the International Society of Cerebral Blood Flow and Metabolism

دوره 13 1  شماره 

صفحات  -

تاریخ انتشار 1993