HPLC-MRM relative quantification analysis of fatty acids based on a novel derivatization strategy.
نویسندگان
چکیده
Fatty acids (FAs) are associated with a series of diseases including tumors, diabetes, and heart diseases. As potential biomarkers, FAs have attracted increasing attention from both biological researchers and the pharmaceutical industry. However, poor ionization efficiency, extreme diversity, strict dependence on internal standards and complicated multiple reaction monitoring (MRM) optimization protocols have challenged efforts to quantify FAs. In this work, a novel derivatization strategy based on 2,4-bis(diethylamino)-6-hydrazino-1,3,5-triazine was developed to enable quantification of FAs. The sensitivity of FA detection was significantly enhanced as a result of the derivatization procedure. FA quantities as low as 10 fg could be detected by high-performance liquid chromatography coupled with triple-quadrupole mass spectrometry. General MRM conditions were developed for any FA, which facilitated the quantification and extended the application of the method. The FA quantification strategy based on HPLC-MRM was carried out using deuterated derivatization reagents. "Heavy" derivatization reagents were used as internal standards (ISs) to minimize matrix effects. Prior to statistical analysis, amounts of each FA species were normalized by their corresponding IS, which guaranteed the accuracy and reliability of the method. FA changes in plasma induced by ageing were studied using this strategy. Several FA species were identified as potential ageing biomarkers. The sensitivity, accuracy, reliability, and full coverage of the method ensure that this strategy has strong potential for both biomarker discovery and lipidomic research.
منابع مشابه
Analysis of Plasma Amino Acids Using RP-HPLC and Pre-Column Derivatization with OPA/3-MPA
ABSTRACT Background and Objective: Measurement of amino acids is an important tool for metabolic studies and evaluation of patients’ clinical condition. The aim of this study was to analyze the plasma amino acids using reverse phase high performance liquid chromatography techniques (RP-HPLC) with pre-column derivatization by o-phthalaldehyde (OPA)...
متن کاملQuantification of Free Carnitine and Acylcarnitines in Plasma or Serum Using HPLC/MS/MS.
Acylcarnitines are formed by esterification between fatty acids CoA or organic acids CoA molecules and carnitine. In various fatty acids oxidation defects and organic acidurias, there is increased concentration of corresponding acylcarnitines. Abnormalities in specific acylcarnitines are used in the diagnosis of fatty acids oxidation defects and organic acidurias. Most commonly used method for ...
متن کاملQuantification of underivatized fatty acids from vegetable oils by HPLC with UV detection.
We propose a chromatographic method for the separation of saturated and unsaturated fatty acids by a high-performance liquid chromatography system, equipped with a photo diode array detector. Central to the method is the use of an appropriate mobile phase composed of acetonitrile, methanol, and n-hexane in ratio 90:8:2 acidified with 0.2% acetic acid, which allows the detection of fatty acids w...
متن کاملFast HPLC determination of serum free fatty acids in the picomole range.
We developed a method for determining individual free fatty acids in serum by using a modified one-step Dole extraction, derivatization, and a new high-performance liquid chromatographic (HPLC) separation. Sample handling is minimized to a single transfer of the fatty acids (upper layer of the Dole extract), which are readily derivatized at 85 degrees C with p-bromophenacyl bromide without sign...
متن کاملLiquid Chromatography Tandem Mass/Mass Spectrometry for the Quantification of Fudosteine in Human Serum without Precolumn Derivatization
A quantitative analysis method for fudosteine in human serum by high-performance liquid chromatography-electrospray ionization tandem mass spectrometry (HPLC-ESI/MS/MS) was established, which shows high sensitivity and selectivity. The mobile phase composition was 75% 20 mM acetic acid and 25% acetonitril, which was pumped at a flow rate of 0.40 mL/min. The overall chromatographic run time was ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Analyst
دوره 139 23 شماره
صفحات -
تاریخ انتشار 2014