On the crucial impact of the coupling projector-backprojector in iterative tomographic reconstruction
نویسندگان
چکیده
The performance of an iterative reconstruction algorithm for X-ray tomography is strongly determined by the features of the used forward and backprojector. For this reason, a large number of studies has focused on the to design of projectors with increasingly higher accuracy and speed. To what extent the accuracy of an iterative algorithm is affected by the mathematical affinity and the similarity between the actual implementation of the forward and backprojection, referred here as “coupling projector-backprojector”, has been an overlooked aspect so far. The experimental study presented here shows that the reconstruction quality and the convergence of an iterative algorithm greatly rely on a good matching between the implementation of the tomographic operators. In comparison, other aspects like the accuracy of the standalone operators, the usage of physical constraints or the choice of stopping criteria may even play a less relevant role.
منابع مشابه
Conventional Voxel in Tomographic Reconstruction Based upon Plane-Integral Projections – Use It or Lose It?
Introduction: While the necessity of replacing voxels with blobs in conventional tomographic reconstruction based upon line-integrals is clear, it is not however well-investigated in plane- integral-based reconstruction. The problem is more challenging in convergent-plane projection reconstruction. In this work, we are aiming at utilizing blobs as alternative to voxels. <stron...
متن کاملA Rotating and Warping Projector/Backprojector for Fan-Beam and Cone-Beam Iterative Algorithm
A rotating-and-warping projector / backprojector is proposed for iterative algorithms used to reconstruct fanbeam and cone-beam single photon emission computed tomography (SPECT) data. The development of a new projector/ backprojector for implementing attenuation, geometric point response, and scatter models is motivated by the need to reduce the computation time yet to preserve the fidelity of...
متن کاملIterative reconstruction of fluorine-18 SPECT using geometric point response correction.
UNLABELLED This article demonstrates resolution recovery in 18F SPECT image reconstruction by using an iterative algorithm that corrects for the system geometric response. METHODS Patient and phantom studies were performed using a Picker PRISM 3000 three-detector SPECT system (Picker International, Inc., Cleveland, OH) to image 18F with 511 keV collimators. A measured point response function ...
متن کاملFourier-based forward and back projectors for iterative tomographic image reconstruction
Forward projectors are needed for iterative image reconstruction algorithms for CT or PET image reconstruction. The major cost of iterative reconstruction algorithms is computing the forward and backward projections. Conventionally, this is done in the image domain as computing the lengths of intersections between each X-ray ray and each image voxel. These operations are the major computational...
متن کاملFourier-Based Forward and Back-Projectors for Iterative Image Reconstruction
Iterative image reconstruction algorithms play an increasingly important role in modern tomographic systems, especially in emission tomography. With the fast increase of the sizes of the tomographic data, reduction of the computation demands of the reconstruction algorithms is of great importance. Fourier-based forward and back-projection methods have the potential to considerably reduce the co...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- CoRR
دوره abs/1612.05515 شماره
صفحات -