Atrophic ununited diaphyseal fractures of the humerus with a bony defect: treatment by wave-plate osteosynthesis.
نویسندگان
چکیده
We treated 15 patients with atrophic nonunion of a diaphyseal fracture of the humerus with an associated bony defect using an autogenous cancellous bone graft and a plate to bridge the defect. There were nine men and six women with a mean age of 48 years. The mean length of the bony defect was 3 cm. At a mean follow-up of 30 months only one fracture failed to unite. This suggests that, in the presence of a well-vascularised envelope of muscle, the application of an autogenous cancellous bone graft in conjunction with a bridging plate represents a good alternative to more demanding surgical techniques.
منابع مشابه
[Treatment of humeral shaft fractures using Hackethal's technique of intramedullary bundle nailing].
PURPOSE OF THE STUDY To inform on our experience with the treatment of humeral shaft fractures by intramedullary osteosynthesis using Hackethal's bundle nailing and to evaluate indications for the current use of this technique. MATERIAL AND METHODS From January 2001 to December 2009, a total of 184 patients with humeral shaft fractures were treated surgically and, of these, 147 by Hackethal's n...
متن کاملMinimally invasive plate osteosynthesis of the humeral shaft
Although conservative management of humeral diaphyseal fractures has shown good results in about 90% of cases [1, 2], there are both absolute and relative indications for surgical treatment, such as polytrauma, open fractures, bilateral fractures, floating elbow, etc [3]. Minimally invasive surgical techniques in diaphyseal fractures of long bones have shown advantages over the open conventiona...
متن کاملComplex nonunion of fractures of the femoral shaft treated by wave-plate osteosynthesis.
We have treated 42 consecutive complex ununited fractures of the femoral shaft by wave-plate osteosynthesis at five different medical centres. There were 13 with previous infection, 12 with segmental cortical defects, and 3 were pathological fractures. In 39 cases there had been previous internal fixation and 21 patients had had more than one earlier operation. Union was achieved in 41 patients...
متن کاملMinimal invasive ostheosintesis for treatment of diaphiseal transverse humeral shaft fractures
OBJECTIVE To evaluate patients with transverse fractures of the shaft of the humerus treated with indirect reduction and internal fixation with plate and screws through minimally invasive technique. METHODS Inclusion criteria were adult patients with transverse diaphyseal fractures of the humerus closed, isolated or not occurring within 15 days of the initial trauma. Exclusion criteria were p...
متن کاملMinimally Invasive Plate Osteosynthesis with Conventional Compression Plate for Diaphyseal Tibia Fracture.
The diaphyseal tibia fracture is best treated with intramedullary nail but in some cases where the nail is not applicable, plate fixation will be the next option of fixation. The extensile anterior approach is normally used for conventional compression plate fixation in tibia shaft fractures. The extensive surgical dissection may devitalizes the bony fragments and interfere with the fracture un...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- The Journal of bone and joint surgery. British volume
دوره 82 6 شماره
صفحات -
تاریخ انتشار 2000