Electrically detected magnetic resonance using radio-frequency reflectometry.

نویسندگان

  • H Huebl
  • R P Starrett
  • D R McCamey
  • A J Ferguson
  • L H Willems van Beveren
چکیده

The authors demonstrate readout of electrically detected magnetic resonance at radio frequencies by means of a LCR tank circuit. Applied to a silicon field-effect transistor at millikelvin temperatures, this method shows a 25-fold increased signal-to-noise ratio of the conduction band electron spin resonance and a higher operational bandwidth of >300 kHz compared to the kilohertz bandwidth of conventional readout techniques. This increase in temporal resolution provides a method for future direct observations of spin dynamics in the electrical device characteristics.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

3-D RF Coil Design Considerations for MRI

High-frequency coils are widely used in medical applications, such as Magnetic Resonance Imaging (MRI) systems. A typical medical MRI includes a local radio frequency transmit/receive coil. This coil is designed for maximum energy transfer or wave transfer through magnetic resonance. Mutual inductance is a dynamic parameter that determines the energy quantity to be transferred wirelessly by ele...

متن کامل

A longitudinally detected high-field ESR spectrometer for the measurement of spin-lattice relaxation times.

We describe a high-field longitudinally detected electron spin resonance (LOD-ESR) spectrometer operating at 35 and 75 GHz. The lack of resonant microwave circuits facilitates operation at different microwave frequencies without changing the probehead. A very low noise radio frequency detection compensates partially the resulting low sensitivity. The major elements of the LOD-ESR spectrometer a...

متن کامل

Fault Isolation of Open Defects Using Space Domain Reflectometry

Recently, a new approach for isolation of open faults in integrated circuits (ICs) was developed. It is based on mapping the radio-frequency (RF) magnetic field produced by the defective part fed with RF probing current, giving the name to Space Domain Reflectometry (SDR). SDR is a noncontact and nondestructive technique to localize open defects in package substrates, interconnections and semic...

متن کامل

Lock-in detection for pulsed electrically detected magnetic resonance.

We show that in pulsed electrically detected magnetic resonance (pEDMR) signal modulation in combination with a lock-in detection scheme can reduce the low-frequency noise level by one order of magnitude and in addition removes the microwave-induced non-resonant background. This is exemplarily demonstrated for spin-echo measurements in phosphorus-doped silicon. The modulation of the signal is a...

متن کامل

Geometric distortion evaluation of magnetic resonance images by a new large field of view phantom for magnetic resonance based radiotherapy purposes

Background: The magnetic resonance imaging (MRI)-based radiotherapy planning method have been considered in recent years because of the advantages of MRI and the problems of planning with two images modality. The first step in MRI-based radiotherapy is to evaluate magnetic resonance (MR) images geometric distortion. Therefore, the present study aimed to evaluate system related geometric distort...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • The Review of scientific instruments

دوره 80 11  شماره 

صفحات  -

تاریخ انتشار 2009