Misalignment of total ankle components can induce high joint contact pressures.
نویسندگان
چکیده
BACKGROUND A major cause of the limited longevity of total ankle replacements is premature polyethylene component wear, which can be induced by high joint contact pressures. We implemented a computational model to parametrically explore the hypothesis that intercomponent positioning deviating from the manufacturer's recommendations can result in pressure distributions that may predispose to wear of the polyethylene insert. We also investigated the hypothesis that a modern mobile-bearing design may be able to better compensate for imposed misalignments compared with an early two-component design. METHODS Two finite element models of total ankle replacement prostheses were built to quantify peak and average contact pressures on the polyethylene insert surfaces. Models were validated by biomechanical testing of the two implant designs with use of pressure-sensitive film. The validated models were configured to replicate three potential misalignments with the most CLINICAL RELEVANCE version of the tibial component, version of the talar component, and relative component rotation of the two-component design. The misalignments were simulated with use of the computer model with physiologically relevant boundary loads. RESULTS With use of the manufacturer's guidelines for positioning of the two-component design, the predicted average joint contact pressures exceeded the yield stress of polyethylene (18 to 20 MPa). Pressure magnitudes increased as implant alignment was systematically deviated from this reference position. The three-component design showed lower-magnitude contact pressures in the standard position (<10 MPa) and was generally less sensitive to misalignment. Both implant systems were sensitive to version misalignment. CONCLUSIONS In the tested implants, a highly congruent mobile-bearing total ankle replacement design yields more evenly distributed and lower-magnitude joint contact pressures than a less congruent design. Although the mobile-bearing implant reduced susceptibility to aberrant joint contact characteristics that were induced by misalignment, predicted average contact stresses reached the yield stress of polyethylene for imposed version misalignments of >5 degrees.
منابع مشابه
Finite element analysis of a total ankle replacement during the stance phase of gait.
Total ankle replacement (TAR) designs have still several important issues to be addressed before the treatment becomes fully acceptable clinically. Very little is known about the performance, in terms of the contact pressures and kinematics of TAR when subjected to daily activities such as level gait. For this purpose, an explicit finite element model of a novel 3-component TAR was developed, w...
متن کاملEvaluation of Changes in the Tibiotalar joint after High Tibial Osteotomy
Background: There are limited studies regarding the effects of high tibial osteotomy (HTO) on other areas of lower extremity. In current study, we investigated the changes of tibiotalar joint following HTO. Methods: A total of 39 patients with genu varum requiring HTO were enrolled in this before and after study. The genu varus, joint diversion (JDA), lateral distal tibial (LDTA) and lateral d...
متن کاملNovel metallic implantation technique for osteochondral defects of the medial talar dome
BACKGROUND AND PURPOSE A metallic inlay implant (HemiCAP) with 15 offset sizes has been developed for the treatment of localized osteochondral defects of the medial talar dome. The aim of this study was to test the following hypotheses: (1) a matching offset size is available for each talus, (2) the prosthetic device can be reproducibly implanted slightly recessed in relation to the talar carti...
متن کاملPlantar pressures in fiberglass total contact casts vs. a new diabetic walking boot.
The objective of this study was to determine in healthy individuals whether the Bledsoe Diabetic Conformer Boot reduces plantar pressures as well as a fiberglass total contact cast. Eighteen normal subjects, without any prior foot or ankle problems, were recruited for this study. Plantar pressures were measured using the Novel Pedar in-shoe pressure measurement system. The results of this study...
متن کاملDesign enhancement of a solid ankle-foot orthosis: real-time contact pressures evaluation.
The purpose of our study was to evaluate all contact pressures between the molded ankle-foot orthosis (MAFO) and the subject during activities of daily living. The MAFOs studied are used clinically to reduce plantar contact pressures associated with foot ulcers in adult neuropathic diabetic subjects, alleviating abnormal pressures by redistributing them to low-pressure plantar regions. While ef...