Aortic valve replacement through full sternotomy with a stented bioprosthesis versus minimally invasive sternotomy with a sutureless bioprosthesis.

نویسندگان

  • Magnus Dalén
  • Fausto Biancari
  • Antonino S Rubino
  • Giuseppe Santarpino
  • Natalie Glaser
  • Herbert De Praetere
  • Keiichiro Kasama
  • Tatu Juvonen
  • Wanda Deste
  • Francesco Pollari
  • Bart Meuris
  • Theodor Fischlein
  • Carmelo Mignosa
  • Giuseppe Gatti
  • Aniello Pappalardo
  • Peter Svenarud
  • Ulrik Sartipy
چکیده

OBJECTIVES The aim of this study was to analyse early postoperative outcomes and 2-year survival after aortic valve replacement (AVR) through a ministernotomy with a sutureless bioprosthesis implantation compared with a full sternotomy with implantation of a stented bioprosthesis. METHODS Patients who underwent primary isolated non-emergent AVR at six European centres were included in the study. Of these, 182 (32%) underwent a ministernotomy with a sutureless bioprosthesis (ministernotomy sutureless group) and 383 (68%) a full sternotomy with a stented bioprosthesis (full sternotomy stented group). Propensity score matching was used to reduce selection bias. RESULTS In the overall cohort, 30-day mortality was 1.6 and 2.1%, and 2-year survival was 92 and 92% in the ministernotomy sutureless group and in the full sternotomy stented group, respectively. Propensity score matching resulted in 171 pairs with similar characteristics and operative risk. Aortic cross-clamp (40 vs 65 min, P < 0.001) and cardiopulmonary bypass time (69 vs 87 min, P < 0.001) were shorter in the ministernotomy sutureless group. Patients undergoing ministernotomy received less packed red blood cells but the risk for postoperative permanent pacemaker implantation was higher. There were no differences regarding 30-day mortality or 2-year survival between the two groups. CONCLUSIONS AVR through a ministernotomy with implantation of a sutureless bioprosthesis was associated with shorter aortic cross-clamp and cardiopulmonary bypass time and less transfusion of packed red blood cells, but a higher risk for postoperative permanent pacemaker implantation compared with a full sternotomy with a stented bioprosthesis.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Thoracoscopic confirmation of correct seating of minimaly-invasive rapid-deployment aortic bioprosthesis

There is a growing interest in minimally invasive access for aortic valve surgery. The upper hemi-sternotomy provides good aortic valve exposure, with numerous possible advantages. Nevertheless, some surgeons remain skeptical about limited access surgery because it is technically more demanding. Sutureless and rapid-deployment bioprostheses could alleviate these concerns by improving ease of im...

متن کامل

Non-sutureless minimally invasive aortic valve replacement: mini-sternotomy versus mini-thoracotomy: a series of 1130 patients.

OBJECTIVES Aortic valve replacement through conventional sternotomy still represents the gold-standard surgical approach for aortic valve disease. However, given the increasing number of patients with comorbidities, strategies that can improve operative results are always sought. Minimally invasive aortic valve surgery, although related to a steep learning curve, might be associated with improv...

متن کامل

Recent advances in aortic valve replacement for aortic stenosis

Aortic valve replacement is no longer an operation that is approached solely through a median sternotomy. Recent advances in the fields of transcatheter valves have expanded the proportion of patients eligible for intervention. Comparisons between transcatheter valves and conventional surgery have shown non-inferiority of transcatheter valve implants in patients with a high or intermediate pre-...

متن کامل

Off-pump transapical balloon-expandable aortic valve endoprosthesis implantation.

OBJECTIVE The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower mor...

متن کامل

Minimally Invasive Approaches Versus Conventional Sternotomy for Aortic Valve Replacement: A Propensity Score Matching Study

BACKGROUND The aim of this study is to evaluate our institutional results of the aortic valve replacement through minimally invasive approaches compared with conventional sternotomy. MATERIALS AND METHODS From August 1997 to July 2010, 838 patients underwent primary isolated aortic valve replacement. Of them, 73 patients underwent surgery through minimally invasive approaches (MIAS group) whe...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery

دوره 49 1  شماره 

صفحات  -

تاریخ انتشار 2016