Characterization of interfragmentary motion associated with common osteosynthesis devices for rat fracture healing studies
نویسندگان
چکیده
Rat models are widely used in preclinical studies investigating fracture healing. The interfragmentary movement at a fracture site is critical to the course of healing and therefore demands definition in order to aptly interpret the experimental results. Estimation of this movement requires knowledge of the fixation stiffness and loading. The characteristic loading for the rat femur has been estimated, but the stiffness of fixation used in rat studies has yet to be fully described. This study aimed to determine the 6 degree of freedom stiffness of four commonly used implants, two external fixators (RatExFix and UlmExFix), a locking plate, and a locking intramedullary nail, in all degrees of freedom and estimate the interfragmentary movement under specific physiological loads. The external fixator systems allow the greatest movement. Mounted 45° anterolateral on the femur, the RatExFix allows an average of 0.88 mm of motion in each anatomic direction while the stiffer UlmExFix allows about 0.6 mm of motion. The nail is far stiffer than the other implants investigated while the plate allows movement of an intermediate magnitude. Both the nail and plate demonstrate higher axial than shear stiffness. The relatively large standard deviations in external fixator shear motion imply strong dependence on bone axis alignment across the gap and the precise orientation of the specimen relative to the loading. The smaller standard deviation associated with the nail and plate results from improved alignment and minimization of the influence of rotational positioning of the specimen due to the reduced implant eccentricity relative to the specimen axis. These results show that the interfragmentary movement is complex and varies significantly between fixation devices but establishes a baseline for the evaluation of the results of different studies.
منابع مشابه
DLS 5.0 - The Biomechanical Effects of Dynamic Locking Screws
INTRODUCTION Indirect reduction of dia-/metaphyseal fractures with minimally invasive implant application bridges the fracture zone in order to protect the soft-tissue and blood supply. The goal of this fixation strategy is to allow stable motion at the fracture site to achieve indirect bone healing with callus formation. However, concerns have arisen that the high axial stiffness and eccentric...
متن کاملDoes locked plating of periprosthetic supracondylar femur fractures promote bone healing by callus formation? Two cases with opposite outcomes.
Contemporary locking plates promote biological fixation through indirect reduction techniques and by elevating the plate from the bone. They have improved fixation strength in osteoporotic bone. Periarticular locking plates are rapidly being adopted for bridge plating of periprosthetic femur fractures. When these plates are used for indirect reduction and bridge plating osteosynthesis, fracture...
متن کاملNew method for detection of complex 3D fracture motion - Verification of an optical motion analysis system for biomechanical studies
BACKGROUND Fracture-healing depends on interfragmentary motion. For improved osteosynthesis and fracture-healing, the micromotion between fracture fragments is undergoing intensive research. The detection of 3D micromotions at the fracture gap still presents a challenge for conventional tactile measurement systems. Optical measurement systems may be easier to use than conventional systems, but,...
متن کاملComparison of 4 Methods for Dynamization of Locking Plates: Differences in the Amount and Type of Fracture Motion
BACKGROUND Decreasing the stiffness of locked plating constructs can promote natural fracture healing by controlled dynamization of the fracture. This biomechanical study compared the effect of 4 different stiffness reduction methods on interfragmentary motion by measuring axial motion and shear motion at the fracture site. METHODS Distal femur locking plates were applied to bridge a metadiap...
متن کاملPercutaneous Cannulated Compression Screw Osteosynthesis in Phalanx Fractures: The Surgical Technique, the Indications, and the Results
Objective: Fractures of metacarpals and phalanges are very common fractures, and there are a lot of treatment modalities. The purpose of the study was to describe the technique of percutaneous fixation of phalangeal fractures using a cannulated compression screw fixation system and its results. Methods: We conducted a prospective clinical study on 43 patients with different types of phalangeal ...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره 12 شماره
صفحات -
تاریخ انتشار 2017