A Drop Tower Protocol with Advanced Pulse Shaping for Hip Fracture Simulation
نویسندگان
چکیده
Force traces from isolated pelvis impact tests [1] have a bimodal behaviour with each local maximum having nearly the same magnitude, but the first having a lower duration. We believe that the initial force peak in this data was caused by the inertia of the femoral head and lateral pelvis, which are almost rigidly connected to the femoral neck. To date, test apparatuses used to model falls to the side have not reproduced the inertia of these structures but instead have focused on modelling the inertia of the body delivered through the pelvis. The rate of loading will affect the strain rate in the femoral neck; since bone properties are influence by strain rate, we believe that this initial, high-rate pulse could be critical to modelling and understanding the behaviour of the proximal femur in a sideways fall. To this end, we sought to include models of the tissues and structures surrounding the femur in a drop tower simulation of a sideways fall, replicating their inertial effects and elastic properties.
منابع مشابه
The Assessment of Second Pulse Effects on the Microstructure and Fracture Behavior of the Resistance Spot Welding in Advanced Ultrahigh-Strength Steel TRIP1100
In this study, the effects of the second pulse resistance spot welding on the microstructure and mechanical properties of TRIP1100 steel were evaluated. The thermal process after welding was designed to improve metallurgical properties with pulse currents of 6kA, 9kA and 12kA after initial welding with 10kA current. The effect of the second pulse on mechanical and microstructural properties was...
متن کاملFailure in the Proximal Femur in Simulated Sideways Fall Impact
The biomechanics of hip fractures has been studied by many authors in the past; however, predictions of the fracture location and character remain difficult and speculative. The aims of the present study are threefold. First, to investigate whether proximal femur trochanteric and cervical geometrical metrics correlate with outcomes of dynamic drop tower testing carried out on human donor femurs...
متن کاملThe effect of micro/nano-particles on pressure drop in Oil pipeline: Simulation
A high pressure drop happens when heavy oil with high viscosity moves through the oil pipeline. A variety of methods to avoid this pressure drop is available. One of which is injection of chemicals to reduce the viscosity and ultimately reduce pressure drop. Using the pipesim software, the effect of dispersion of nano and micro-particles into the oil has been simulated to study the amount of th...
متن کاملEconomic Analysis of Bisphosphonate Use after Distal Radius Fracture for Prevention of Hip Fracture
Background: Osteoporosis is a common condition among the elderly population, and is associated with an increased risk of fracture. One of the most common fragility fractures involve the distal radius, and are associated with risk of subsequent fragility fracture. Early treatment with bisphosphonates has been suggested to decrease the population hip fracture burden. However, there have been no p...
متن کاملRecurrent hip fracture prevention with osteoporosis management
Abstract Background: Osteoporosis is a major public health threat, and hip fracture is a serious consequence of osteoporosis. Apatient with an osteoporosis-related hip fracture has an increased risk for a second hip fracture. The effect of osteoporosis management on the risk of recurrent hip fracture was evaluated in this study. Methods: 58 hip fracture patients older than 50yr and BMD < 2.5 w...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -
تاریخ انتشار 2012