On 4D-Hawing Radiation from Effective Action
نویسندگان
چکیده
We determine the s-waves contribution of a scalar field to the four dimensional effective action for arbitrary spherically symmetric external gravitational fields. The result is applied to 4d-black holes and it is shown that the energy momentum tensor derived from the (nonlocal) effective action contains the Hawking radiation. The luminosity is close to the expected one in the s-channel. The energy momentum tensor may be used as starting point to study the backreaction problem.
منابع مشابه
A Simulation Study on Patient Setup Errors in External Beam Radiotherapy Using an Anthropomorphic 4D Phantom
Introduction Patient set-up optimization is required in radiotherapy to fill the accuracy gap between personalized treatment planning and uncertainties in the irradiation set-up. In this study, we aimed to develop a new method based on neural network to estimate patient geometrical setup using 4-dimensional (4D) XCAT anthropomorphic phantom. Materials and Methods To access 4D modeling of motion...
متن کامل/ 98 06 24 5 v 1 3 0 Ju n 19 98 Evaporation of Schwarszchild Black Hole in the Large N Matrix Theory
By using the D0-brane cluster picture, we consider the Hawking radiation of Schwarszchild black hole (SBH) in large N Matrix model. We get the correct formula for the the Hawing evaporation rate. Our result give some evidence on the Lorentz invariance of the physics of Matrix model.
متن کامل/ 98 06 24 5 v 2 7 J ul 1 99 8 Evaporation of Schwarzschild Black Hole in the Large N Matrix Theory
By using the D0-brane cluster picture, we consider the Hawking radiation of Schwarzschild black hole (SBH) in large N Matrix model. We get the correct formula for the the Hawing evaporation rate. Our results give some evidence on the Lorentz invariance of the physics of Matrix model.
متن کاملEstimation of Radiation Exposure of 128-Slice 4D-Perfusion CT for the Assessment of Tumor Vascularity
OBJECTIVE We aimed to estimate the effective dose of 4D-Perfusion-CT protocols of the lung, liver, and pelvis for the assessment of tumor vascularity. MATERIALS AND METHODS An Alderson-Rando phantom equipped with thermoluminescent dosimeters was used to determine the effective dose values of 4D-Perfusion-CT. Phantom measurements were performed on a 128-slice single-source scanner in adaptive ...
متن کاملVariation of annual effective dose from external ionizing radiation among radiation workers of Bahawalpur Institute of Nuclear Medicine and Oncology (BINO), Pakistan
Background: The aim of the study was to analyze the effective dose record of occupationally exposed radiation workers at Bahawalpur Institute of Nuclear Medicine and Oncology department. Materials and Methods: Annual effective doses of occupationally exposed workers were measured by film badge dosimetry by sending the dosimeters to Radiation Dosimetry Laboratory (RDL), Pakistan Institute of Nuc...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
دوره شماره
صفحات -