A Short Study Report For Phantom Investigation

نویسنده

  • Rongguang Han
چکیده

1. Polyvinyl Alcohol Phantoms (Polyvinyl alcohol gels) Polyvinyl alcohol cryogel (PVA-C) is a typical tissue-mimicking material for ultrasound imaging. It is formed from PVA solution undergoing some freezethaw (F/T) cycles. As the optical and mechanical properties change with the number of F/T cycle, certain requirements, like the scattering coefficient and absorption coefficient, for the phantom can be achieved. This phantom can be used in a permanent way under humidity-controlled conditions. PVA can be obtained from Sigma-Aldrich (catalog number 36 314-6) [5], Acros organics (Geel, Belgium) [2] or Airvol Grade 165 PVA powder (Air Products and Chemicals, Inc; Allentown, PA) [6]. Detailed construction process is discussed in [2]. The brief idea is shown below: 1) 5% or 8% by weight PVA are dissolved in distilled water. And this solution is heated for about 7 hours at the temperature of 93 to 95 degree Celsius. 2) The PVA solution is cooled to -25 to -20 degree Celsius for about 12 hours. Then, the solution will warm back to room temperature in a continuous way for another 12 hours. If needed, this F/T cycle can be repeated for several times. Without the addition of dimethyl sufoxide (DMSO), the scattering coefficient will increase with each cycle and the phantom will be stiffer, too. 3) Brain Mold is prepared using Colin27 data set. 4) Approximating the live Brain Texture. (Useful data from [2]: 6% PVA solution at 1 FTC is similar to palpating the surface of a live brain and 4% PVA at 3FTC as being similar to palpating a low-grade gliomas.) 5) Implants for registration and image guidance are included.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Ilizarov Stump Lenthening Can Aggravate Phantom Limb Pain – a Case Report

Ilizarov is an accepted technique for lengthening short amputation stumps to improve prosthetic function andrehabilitation. The relation of stump lengthening and phantom limb pain (PLP) has not been reported in literature.We present here a case report of a transfemoral amputee who had a flare up of PLP following stump lengthening.He responded well to a combination of pharmacological therapy and...

متن کامل

Image-based versus atlas-based patient-specific S-value assessment for Samarium-153 EDTMP cancer palliative care: A short study

Introduction: Use of SPECT/CT data is the most accurate method for patient-specific internal dosimetry when isotopes emit single gamma rays. The manual or semi-automatic segmentation of organs is a major obstacle that slows down and limits the patient-specific dosimetry. Using digital phantoms that mimic patient’s anatomy can bypass the segmentation step and facilitate the dosi...

متن کامل

Ultra-short echo time magnetic resonance imaging for detection of pulmonary arteriovenous malformation recanalization after coil embolization: a case report and a phantom study

A pulmonary arteriovenous malformation (PAVM) is a direct connection between the pulmonary arteries and veins for which metallic coil transcatheter embolization is the standard of care. Detecting recanalization after PAVM treatment is crucial, but direct visualization with computed tomography or magnetic resonance imaging (MRI) is generally difficult. Here, we report a case of a recanalized PAV...

متن کامل

A dosimetric study of deep skin electron therapy with overlapping stationary radiation fields – A case report

Background: For radiotherapy of total skin including sub-cutaneous tissue up to a depth of 3 cm on the entire left leg of an adult (Angiosarcoma skin), a complex treatment with multiple stationary electron fields was planned at our clinic. The details of dosimetry, clinical dose measurements are presented. Materials and Methods: The treatment planned with 6 overlapping 9 MeV electron fields in ...

متن کامل

یک فانتوم سر ریاضیاتی برای بررسی‌های دوزیمتری به روش مونت‌کارلو

Introduction: In diagnostic and therapeutic procedures, dosimetric studies are performed on the dosimetric systems in order to comply the radiation safety standards. Monte Carlo methods are used due to the high complexity and cost of patient-specific phantom construction. The high complexity of the digitized phantoms greatly increases the time and computational task of the Monte Carlo calculati...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2013