[Improving the visualization of non-absorbable T-Flux(®) implants in deep sclerectomy. Colouring technique].

نویسندگان

  • K Schargel
  • J Placeres-Daban
  • V Garcia-Conca
  • J I Belda
  • F Aguirre Balsalobre
چکیده

PURPOSE To describe a staining technique that will enhance the visualization of non-absorbable T-Flux implants. METHODS The technique was applied to non-absorbable T-Flux implants. The implants were submerged for 5 to 10 minutes in a sodium fluorescein solution, and dried with a sponge when removed from the solution. DISCUSSION This is a very simple and easy procedure that uses a common fluorescein solution to enhance the contrast between the surgical field and a transparent implant used in deep sclerectomy. This colour technique will decrease the risk of loss of the implant in the surgical field.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Intrascleral outflow after deep sclerectomy with absorbable and non-absorbable implants in the rabbit eye

BACKGROUND The purpose of the study is an analysis of intrascleral drainage vessels formed in rabbits' eyes after non-penetrating deep sclerectomy (NPDS) with absorbable and non-absorbable implants, and comparison to eyes in which surgery was performed without implanted material. MATERIAL/METHODS NPDS was carried out in 12 rabbits, with implantation of non-absorbable methacrylic hydrogel (N=1...

متن کامل

[Ultrasound biomicroscopy in deep sclerectomy with a new acrylic implant].

OBJECTIVE To describe the ultrasound biomicroscopic (UBM) characteristics seen in patients who have undergone deep phaco-sclerectomy with a new acrylic implant (Esnoper). SUBJECTS, MATERIAL AND METHODS UBM exploration was performed 12 months after deep phaco-sclerectomy in three patients with chronic open angle glaucoma. RESULTS One year after surgery, all three patients had intraocular pre...

متن کامل

Biodegradable Collagen Implants in Trabeculectomy.

Subconjunctival and subscleral fibrosis are the major causes of failure of filtering surgery. Antiproliferative agents have been successfully used to improve the long-term success of this surgery. Recent advancement in the field of glaucoma surgery has been the use of bioengineered, biodegradable, porous collagen-glycosaminoglycan matrix implant in the subconjunctival and/or subscleral space to...

متن کامل

A New Implant for Deep Sclerectomy: Esnoper®

Newer non-reabsorbing implants have been developed to maintain the hypotensor effect of nonpenetrating deep sclerectomy. In this article the authors discuss a new non-reabsorbing implant with 2-hydroxyethyl methacrylate (Esnoper®, AJL Ophthalmics, SA, Miñano, Alava, Spain), its design, technique of implantation and the available scientific evidence.

متن کامل

SKGEL® Implant Versus T-Flux® Implant in the Contralateral Eye in Deep Sclerectomy with Phacoemulsification: Long-Term Follow-Up

PURPOSE To intraindividually compare the efficacy and safety of the SKGEL(®) implant versus the T-Flux(®) implant in deep sclerectomy. METHODS In a retrospective analysis 17 patients were identified who underwent combined phacoemulsification-deep sclerectomy and implantation of SKGEL(®) in one eye and T-Flux(®) in the contralateral eye. RESULTS In eyes with SKGEL(®) the IOP decreased from 2...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:
  • Archivos de la Sociedad Espanola de Oftalmologia

دوره 89 6  شماره 

صفحات  -

تاریخ انتشار 2014