Preliminary study of ergonomic behavior during simulated ultrasound-guided regional anesthesia using a head-mounted display.
نویسندگان
چکیده
A head-mounted display provides continuous real-time imaging within the practitioner's visual field. We evaluated the feasibility of using head-mounted display technology to improve ergonomics in ultrasound-guided regional anesthesia in a simulated environment. Two anesthesiologists performed an equal number of ultrasound-guided popliteal-sciatic nerve blocks using the head-mounted display on a porcine hindquarter, and an independent observer assessed each practitioner's ergonomics (eg, head turning, arching, eye movements, and needle manipulation) and the overall block quality based on the injectate spread around the target nerve for each procedure. Both practitioners performed their procedures without directly viewing the ultrasound monitor, and neither practitioner showed poor ergonomic behavior. Head-mounted display technology may offer potential advantages during ultrasound-guided regional anesthesia.
منابع مشابه
Ergonomic task analysis of ultrasound-guided femoral nerve block: a pilot study.
STUDY OBJECTIVE To apply ergonomic task analysis to the performance of ultrasound-guided (US-guided) femoral nerve block (FNB) in an acute hospital setting. DESIGN Pilot prospective observational study. SETTING Orthopedic operating room of a regional trauma hospital. SUBJECTS 15 anesthesiologists of various levels of experience in US-guided FNB (estimated minimum experience < 10 procedure...
متن کاملTowards Performing Ultrasound-Guided Needle Biopsies from within a Head-Mounted Display
Augmented reality is applied to ultrasound-guided needle biopsy of the human breast. In a tracked stereoscopic head-mounted display, a physician sees the ultrasound imagery “emanating” from the transducer, properly registered with the patient and the biopsy needle. A physician has successfully used the system to guide a needle into a synthetic tumor within a breast phantom and examine a human p...
متن کاملCurrent concepts and future trends in ultrasound-guided regional anesthesia.
PURPOSE OF REVIEW Ultrasound guidance for regional anesthesia has gained enormous popularity during the past several years. This review article highlights the importance of acquiring an understanding and knowledge of human anatomy for well tolerated and effective performance of regional anesthesia; includes description of some of the major principles of ultrasound-guided regional anesthesia tec...
متن کاملUltrasound-guided regional anesthesia: current concepts and future trends.
The scope of ultrasound imaging guidance for regional anesthesia is growing rapidly. Preliminary data, although limited, suggest that ultrasound can improve block success rate and decrease complications. In this review, we describe the basic principles of ultrasound scanning and needling techniques for nerve blocks, highlight some of the data on clinical outcome, discuss specific limitations of...
متن کاملUltrasound- guided Hydrostatic (Hydrocolonic) Treatment of Meconium Ileus: A Preliminary Report
Background Meconium ileus (MI) is one type intestinal obstruction due to inspissated meconium at the level of the terminal ileum. The purpose of this study is to present the non-ionizing ultrasound-guided approach for the treatment of meconium ileus. Materials and Methods This study was performed, prospectively, at Dr. Sheikh and Akbar children's Hospitals, Mashhad University of Medical Science...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Journal of ultrasound in medicine : official journal of the American Institute of Ultrasound in Medicine
دوره 31 8 شماره
صفحات -
تاریخ انتشار 2012