Rate-nephelometric inhibition immunoassay of phenytoin and phenobarbital.
نویسندگان
چکیده
A proposed rate-nephelometric inhibition immunoassay of phenytoin and phenobarbital in human serum involves the sequential addition to buffer of 42-microL aliquots of sample containing the hapten (drug) of interest, a hapten conjugate (drug-equine apoferritin), and specific antibody to the hapten. The drug and the drug conjugate compete for the binding sites on the antibody. The free hapten-antibody complex is soluble and so does not scatter light, whereas the complex of antibody and drug conjugate is insoluble and thus scatters light. The latter immunoprecipitation is competitively inhibited by free hapten. Thus the higher the concentration of free hapten present, the fewer immunoprecipitin complexes are formed, and the less light scatter. Precision, accuracy, linearity, analytical recovery, and comparison with patients' samples assayed with the DuPont aca were excellent. There was no significant interference from hemolysis, icterus, or lipemia. Many potentially interfering drugs and metabolites were checked for cross reactivity, with negative results. Reaction times range from 30 to 50 s.
منابع مشابه
Use of saliva in therapeutic drug monitoring.
We measured the concentrations of phenobarbital, phenytoin, primidone, ethosuximide, antipyrine, and caffeine in paired samples of saliva and plasma by gas chromatograph-mass spectrometer-computer (GC/MS/COM) and enzyme immunoassay. Mixed saliva was collected for the antipyrine and caffeine studies, parotid saliva for the phenobarbital, primidone, ethosuximide and phenytoin studies. The saliva/...
متن کاملمطالعه نقش اسید فولیک در کاهش ناهنجاری های تکوینی ناشی از فنی تویین و فنوباربیتال در جنین های موش
Background and purpose: Ëpilepsy is a chronic nervous disease, inflicting about 1٪ of the world population. Toxic effects of antiepileptic drugs are significant and controversial issues. Since these drugs are used by millions of people, the least abnormalities could be presented as a hazardous defect. Âim of this study was to investigate the toxic effects of phenytoin and Phenobarbital. Âmong...
متن کاملEnzyme immunoassays with the miniature centrifugal fast analyzer.
We studied the EMIT (Enzyme Multiplied Immunoassay Technique, Syva) procedures for the assay of phenytoin and phenobarbital in serum, adapting them to the miniature Centrifugal Fast Analyzer. For different concentrations of drug, each rate of reaction decreased continuously with time, tending to converge on a single common value. The rate was most affected by the concentration of drug almost im...
متن کاملمقایسهی سطح سرمی فنوباربیتال و فنیتوئین بین کودکان مبتلا به صرع پایدار و صرع پایدار مقاوم
Background & objective: Due to high kinetic variation of antiepileptic medications in children, judgment on the efficacy of intravenous phenytoin and phenobarbital in treatment of refractory status epilepsy, requires measurement of serum levels of the drugs. The aim of this study was determine and compare serum levels of phenytoin and phenobarbital, as the two major and common first- line drugs...
متن کاملAutomated homogeneous liposome immunoassay systems for anticonvulsant drugs.
We developed automated homogeneous immunoassays, based on immunolysis of liposomes, for measuring phenytoin, phenobarbital, and carbamazepine from serum. Liposome lysis was detected spectrophotometrically from entrapped glucose-6-phosphate dehydrogenase activity. The procedure was fully automated on a routine automated clinical analyzer. Within-run, between-run, dilution, and recovery tests sho...
متن کاملذخیره در منابع من
با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید
عنوان ژورنال:
- Clinical chemistry
دوره 27 3 شماره
صفحات -
تاریخ انتشار 1981