Spin-Echo Micro-MRI of Trabecular Bone Using an Improved 3D FLASE Sequence

نویسندگان

  • J. Magland
  • C. Jones
  • M. Wald
  • F. W. Wehrli
چکیده

Introduction The recognition of the role of trabecular bone (TB) architecture as an independent predictor of bone strength has spurred the development of noninvasive imaging methods. Recent advances in imaging technology now permit in vivo imaging of TB at a resolution adequate for analysis of the 3D architecture of the TB network [1]. Spin-echo imaging has proven to be advantageous since it is less sensitive to the deleterious effects from local gradients at the bone-bone marrow interface [2]. 3D FLASE [3, 4] is a high flip-angle pulse sequence enabling scanning at a high resolution in a clinically practical scan time. The version of the method used previously had limitations, including stimulated echo artifacts from imperfections in the nonselective phase-reversal pulse and poor motion tracking of the gradient-echo navigators. Here we report a significantly improved pulse sequence that resolves these shortcomings. Theory and Methods The FLASE pulse sequences (original and modified) are shown in Figure 2; the modified sequence incorporates a number of improvements in areas of artifact suppression and motion correction. Because the 180 degree refocusing pulse is non-selective, there is a potential for magnetization to be excited outside of the field of view. Indeed, even modest B1 field inhomogeneity can cause undesired transverse magnetization to be excited over a large volume, often causing spurious echoes during imaging. Within a single repetition, this problem can be handled very well using crusher gradients and phase cycling (to push any artifacts to the edge of the field of view). A more serious problem occurs when magnetization is refocused and appears in a subsequent repetition as a stimulated echo, causing a banding (streaking lines) artifact (see Figure 1 and [5]). This complex phenomenon is difficult to predict or correct, as the effect varies from one subject to the next. To overcome these problems, two modifications were made to the pulse sequence. First, the prephasing of the readout gradient is placed after (rather than before) the refocusing pulse (at the expense of a small increase in TE). This ensures that any stimulated echo will at least not be offset from the main echo in the kX direction (eliminating the possibility of banding). Second, a random offset to the transmit/receive phase is applied at the beginning of each repetition, causing any systematic stimulated echoes to be phase-incoherent, and preventing localized artifacts from appearing in image space. The new FLASE protocol also includes improved navigator motion detection. Rather than using magnetization left over from the imaging signal [4], the new protocol includes a separate excitation pulse for the navigator acquisition. In order to avoid a loss in SNR efficiency, a slice adjacent to the imaging slab is excited. In this manner, the navigator signal-to-noise ratio is enhanced thereby improving overall sensitivity in motion detection (see [6]). Finally, in order to reduce aliasing artifacts caused by a too-small FOV in the phase-encode direction (Figure 1), the corners of kYZ space are not acquired in the modified protocol, i.e. a cylindrical k-space volume is acquired. The time saved is used to increase the FOV in the in-plane phase-encoding direction, preventing FOV wrapping into the region of interest. Results The improved FLASE pulse sequence was used in a clinical research study currently in progress involving over fifty scans of the distal tibia. Motion correction seemed to be adequate for most of the scans, and no non-motion related MRI artifacts were observed in any of the images. Figure 3 shows one image acquired with the new protocol. Also, a high-quality 3D skeleton is displayed enabling visualization of the intricate TB architecture. Conclusion A modified 3D FLASE pulse sequence bas been described for micro-MRI of trabecular bone. The new sequence involves a number of improvements in motion correction as well as MRI artifact reduction.

برای دانلود رایگان متن کامل این مقاله و بیش از 32 میلیون مقاله دیگر ابتدا ثبت نام کنید

ثبت نام

اگر عضو سایت هستید لطفا وارد حساب کاربری خود شوید

منابع مشابه

Fast Low-Angle Dual Spin-Echo (FLADE): A New Pulse Sequence for Micro-Imaging of Trabecular Bone

J. Magland, B. Vasilic, F. W. Wehrli Laboratory for Structural NMR Imaging, Department of Radiology, University of Pennsylvania Medical Center, Philadelphia, PA, United States Introduction The architecture of trabecular bone plays a pivotal role in conferring strength to the skeleton. Recent advances in MR imaging technology have made possible direct imaging of the 3D architecture of trabecular...

متن کامل

Performance of two spin-echo sequences for quantitative structure analysis of trabecular bone

Introduction: The susceptibility difference between bone and bone marrow promotes the use of spin echo-based sequences for high resolution magnetic resonance imaging (μMRI) of trabecular bone (TB) [1], particularly for B0>1.5T. At ultra high field strengths, specific absorption rate (SAR) limits for patient safety are breached by the fast large-angle spin-echo (FLASE) pulse sequence. Fast spin ...

متن کامل

High Precision Translational Motion Correction for Micro-MRI of Trabecular Bone Using Cartesian Navigators

optimized protocols; trajectory detected by the former is considerably noisier than the one detected with the optimized navigator protocol. In-vivo Images of the distal tibia corrected with the two navigator p: (a) standard; (b) optimized, yielding NGS values of 0.6548 and 0.8372, respectively. Fig. 1 3D FLASE utilizing a selective RF pulse at t=0 and a non-selective refocusing pulse at time t=...

متن کامل

Development of a compact MRI system for trabecular bone microstructure measurements of the distal radius.

A compact MRI system for trabecular bone (TB) microstructure measurements of the distal radius was developed using a 1.0 T permanent magnet and a compact MRI console. TB microstructure of the distal radius was clearly visualized using a three-dimensional (3D) driven equilibrium spin-echo (DESE) sequence in 23 min. The image obtained had a sufficient spatial resolution (150 microm x 150 microm x...

متن کامل

Assessment of the Characteristics of MRI Coils in Terms of RF Non-Homogeneity Using Routine Spin Echo Sequences

Introduction: One of the major causes of image non-uniformity in MRI is due to the existence of  non-homogeneity in RF receive and transmit. This can be the most effective source of error in  quantitative  studies  in  MRI  imaging.  Part  of  this  non-homogeneity  demonstrates  the  characteristics of RF coil and part of it is due to the interaction of RF field with the material being  imaged...

متن کامل

ذخیره در منابع من


  با ذخیره ی این منبع در منابع من، دسترسی به آن را برای استفاده های بعدی آسان تر کنید

عنوان ژورنال:

دوره   شماره 

صفحات  -

تاریخ انتشار 2007